Related Experiment Video
Updated: Aug 18, 2026

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Resonant amplification of delivered volume during high-frequency ventilation
Abstract:
The volume of gas delivered from a high-frequency ventilation (HFV) circuit was measured with an ultrasonic flowmeter. The measurements were done in vitro (20-liter air-filled glass bottle) and in vivo (9 anesthetized dogs lying supine) at oscillation frequencies ranging from 4 to 23 Hz and stroke volumes of the pump ranging from 36 to 150 ml. We varied the length and diameter of the tube connecting the pump with the endotracheal tube, the length and diameter of the bias outflow tube, the diameter of the endotracheal tube, and the stroke volume of the pump. Both in vitro and in vivo, there was resonant amplification of the delivered gas volume; i.e., the delivered gas volume exceeded the stroke volume at certain frequencies. Altering the dimensions of connecting tube, endotracheal tube, bias outflow tube, or stroke volume, i.e., changing the resistance to gas flow, gas compliance, and/or gas inertance in these elements, altered the ratio of gas delivered to stroke volume that could be predicted by an electric analog. These data indicate that the delivered gas volume during HFV depends critically on the configuration of the HFV circuit, the size of the endotracheal tube, the oscillation frequency, and the pump stroke volume. Knowledge of the delivered gas volume during HFV and appreciation of the phenomenon of resonant amplification of the delivered gas volume will permit a more accurate description of factors contributing to gas transport during HFV.
Related Concept Videos
Sound Waves: Resonance
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...