Background & Aims:
Portosystemic encephalopathy (PSE) is a major complication of trans-jugular intrahepatic porto-systemic shunt (TIPS) placement. Most devices are self-expandable polytetrafluoroethylene-covered stent grafts (PTFE-SGs) that are dilated to their nominal diameter (8 or 10 mm). We investigated whether PTFE-SGs dilated to a smaller caliber (under-dilated TIPS) reduce PSE yet maintain clinical and hemodynamic efficacy. We also studied whether under-dilated TIPS self-expand to nominal diameter over time.
Methods:
We performed a prospective, non-randomized study of 42 unselected patients with cirrhosis who received under-dilated TIPS (7 and 6 mm) and 53 patients who received PTFE-SGs of 8 mm or more (controls) at referral centers in Italy. After completion of this study, dilation to 6 mm became the standard and 47 patients were included in a validation study. All patients were followed for 6 months; Doppler ultrasonography was performed 2 weeks and 3 months after TIPS placement and every 6 months thereafter. Stability of PTFE-SG diameter was evaluated by computed tomography analysis of 226 patients with cirrhosis whose stent grafts increased to 6, 7, 8, 9, or 10 mm. The primary outcomes were incidence of at least 1 episode of PSE grade 2 or higher during follow up, incidence of recurrent variceal hemorrhage or ascites, incidence of shunt dysfunction requiring TIPS recanalization, and reduction in porto-caval pressure gradient.
Results:
PSE developed in a significantly lower proportion of patients with under-dilated TIPS (27%) than controls (54%) during the first year after the procedure (P = .015), but the proportions of patients with recurrent variceal hemorrhage or ascites did not differ significantly between groups. No TIPS occlusions were observed. These results were confirmed in the validation cohort. In an analysis of self-expansion of stent grafts, during a mean follow-up period of 252 days after placement, none of the PTFE-SGs self-expanded to the nominal diameter in hemodynamically relevant sites (such as portal and hepatic vein vascular walls).
Conclusions:
In prospective, non-randomized study of patients with cirrhosis, we found under-dilation of PTFE-SGs during TIPS placement to be feasible, associated with lower rates of PSE, and effective.
More Related Videos
04:09Prospective, Randomized, and Controlled Study of a Human Umbilical Cord Mesenchymal Stem Cell Injection for Treating Diabetic Foot Ulcers
Published on: March 3, 2023
08:36Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
Related Concept Videos
Genome-wide Association Studies-GWAS
GWAS does not require the identification of the target gene involved in...
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Cardiomyopathy II: Dilated Cardiomyopathy
Self-Efficacy
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...