Related Experiment Video
Updated: Feb 15, 2026

Harvest of Vestibular End-Organs under Physiologic Conditions during Labyrinthectomy
Published on: November 29, 2024
Physiologic anisocoria under various lighting conditions
Ryan P Steck1, Min Kong2, Kaydee L McCray3
1Western University of Health Sciences, College of Osteopathic Medicine of the Pacific, Pomona, CA, USA.
Purpose:
To evaluate the measurement of anisocoria in a group of ocular healthy subjects using a standardized protocol in scotopic, mesopic, and photopic lighting conditions, and determine the optimal threshold of difference in pupil diameter in determining physiologic anisocoria.
Methods:
Right and left pupil diameters of 126 ocular healthy subjects with a mean age 30.5±7.8 years (40 males and 86 females) were measured sequentially under photopic conditions using a monocular infrared pupillometer. A sub-group of 51 individuals had right and left pupil measurements performed under three additional lighting conditions, allowing for a 2-minute recovery between measurements. A white light emitting diode (LED) in the eyecup of the pupillometer produced three controlled light settings: scotopic (0 lux), low mesopic (0.3 lux), and high mesopic (3 lux). The criterion for anisocoria was defined as ≥0.4 mm difference in pupil diameter between the eyes.
Results:
In the 126 subjects tested, 23.8% (n=30) exhibited anisocoria in photopic conditions. In the sub-group measured under three additional light settings, 43.1% (n=22) exhibited anisocoria in scotopic conditions, 43.1% (n=22) in low mesopic conditions, and 47.1% (n=24) in high mesopic conditions. Approximately 73% of subjects exhibited anisocoria in at least one light setting, while only approximately 8% had anisocoria in every light setting. When the criterion for anisocoria was shifted to ≥0.2 mm or ≥0.6 mm, the prevalence of anisocoria shifted significantly. Using a higher cutoff of ≥0.6 mm effectively reduced the number of healthy individuals who exhibit anisocoria in every light setting to almost zero.
Conclusion:
Based on our data, anisocoria is more prevalent under varied lighting conditions. To ensure the anisocoria is due to physiologic reasons, one should ensure that it is present under all lighting conditions to avoid excessive false positives.
Related Concept Videos
Photoreceptors and Plant Responses to Light
Physiological Barriers
The blood endothelial barrier is the most porous of these. It allows all small ionized, un-ionized, and lipophilic molecules to pass through the endothelial lining into the interstitial space...
Light Acquisition
Light as Energy
Photons
A photon is a discrete electromagnetic particle or bundle of energy. Photons are characterized by their frequency, wavelength, and amplitude, similar to the properties of a wave. Waves with higher frequencies transmit more energy and have shorter wavelengths than longer wavelengths that transmit...
The Physiology of Taste
Liver Physiology
Metabolic Regulation:
The liver is the central organ involved in regulating blood composition. It stabilizes blood glucose levels, maintaining them within the range of 70–110 mg/dL. When these levels drop, the liver breaks down glycogen reserves and releases glucose into the bloodstream. It can...

