Compatibility and Stability of VARUBI (Rolapitant) Injectable Emulsion Admixed with Intravenous Granisetron

George Wu1, Dan Powers2, Stanley Yeung2

  • 1TESARO, Inc., Waltham, Massachusetts. gwu@tesarobio.com.

Prophylaxis or therapy with a combination of a neurokinin 1 (NK-1) receptor antagonist (RA), a 5-hydroxytryptamine- 3 (5-HT3) RA, and dexamethasone is recommended by international antiemesis guidelines for the prevention of chemotherapy-induced nausea and vomiting for patients receiving highly emetogenic chemotherapy and for select patients receiving moderately emetogenic chemotherapy. VARUBI (rolapitant) is a substance P/NK-1 RA that was recently approved by the U.S. Food and Drug Administration as an injectable emulsion in combination with other antiemetic agents in adults for the prevention of delayed nausea and vomiting associated with initial and repeat courses of emetogenic cancer chemotherapy, including, but not limited to, highly emetogenic chemotherapy. Granisetron Hydrochloride Injection USP is one of the 5-HT3 RAs indicated for the prevention of nausea and/or vomiting associated with initial and repeat courses of emetogenic cancer therapy, including high-dose cisplatin. Herein, we describe the physical and chemical compatibility and stability of VARUBI (rolapitant) injectable emulsion (166.5 mg/92.5 mL [1.8 mg/mL], equivalent to 185 mg of rolapitant hydrochloride) admixed with Granisetron Hydrochloride Injection USP (1.0 mg/mL, equivalent to 1.12 mg/mL hydrochloride). Binary admixtures of VARUBI injectable emulsion and Granisetron Hydrochloride Injection USP were prepared and stored in VARUBI ready-to-use glass vials and in four types of commonly used intravenous administration (tubing) sets. Evaluation of the physical and chemical compatibility and stability of the admixtures in the VARUBI ready-to-use vials stored at room temperature (20°C to 25°C) under fluorescent light and under refrigeration (2°C to 8°C protected from light) was conducted at 0, 1, 6, 24, and 48 hours, and that of the admixtures in the intravenous tubing sets was evaluated at 0, 2, and 6 hours of storage at 20°C to 25°C. Physical stability was evaluated by visual examination of the container contents under normal room light, and measurement of turbidity, globule size, and particulate matter. Chemical stability was assessed by measuring the pH of the admixture and determining drug concentrations (potency) and impurity levels by high-performance liquid chromatographic analysis. The pH, turbidity, globule size, and particulate matter of all samples remained within narrow and acceptable ranges at all study time points, indicating that combining the two formulations into a binary admixture is physically and chemically compatible and stable. VARUBI injectable emulsion admixed with Granisetron Hydrochloride Injection USP demonstrated compatibility and stability in a ready-to-use glass vial for at least 24 hours at room temperature and 48 hours under refrigeration, as well as in the four intravenous tubing sets for at least 6 hours at 20°C to 25°C. No decrease of drug concentration (or potency) of any admixed components occurred in the samples stored at the two conditions and time periods studied based on high-performance liquid chromatographic analysis. The levels of impurities stayed below the safety limits set by International Conference on Harmonisation during the study period.

Related Concept Videos

Nuclear Stability03:18

Nuclear Stability

Protons and neutrons, collectively called nucleons, are packed together tightly in a nucleus. With a radius of about 10−15 meters, a nucleus is quite small compared to the radius of the entire atom, which is about 10−10 meters. Nuclei are extremely dense compared to bulk matter, averaging 1.8 × 1014 grams per cubic centimeter. If the earth’s density were equal to the average nuclear density, the earth’s radius would be only about 200 meters.
To hold positively charged protons together...
23.4K
RNA Stability01:53

RNA Stability

Intact DNA strands can be found in fossils, while scientists sometimes struggle to keep RNA intact under laboratory conditions. The structural variations between RNA and DNA underlie the differences in their stability and longevity. Because DNA is double-stranded, it is inherently more stable. The single-stranded structure of RNA is less stable but also more flexible and can form weak internal bonds. Additionally, most RNAs in the cell are relatively short, while DNA can be up to 250 million...
35.8K
Stability01:28

Stability

The time response of a linear time-invariant (LTI) system can be divided into transient and steady-state responses. The transient response represents the system's initial reaction to a change in input and diminishes to zero over time. In contrast, the steady-state response is the behavior that persists after the transient effects have faded.
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
426
Stability of structures01:14

Stability of structures

In mechanical engineering, the stability of systems under various forces is critical for designing durable and efficient structures. One fundamental way to explore these concepts is by analyzing systems like two rods connected at a pivot point, O, with a torsional spring of spring constant k at the pivot point. This system is similar in appearance to a scissor jack used to change tires on a car. In this case, the arms of the linkage (equivalent to the rods in this system) are entirely vertical,...
534
Pole and System Stability01:24

Pole and System Stability

The transfer function is a fundamental concept representing the ratio of two polynomials. The numerator and denominator encapsulate the system's dynamics. The zeros and poles of this transfer function are critical in determining the system's behavior and stability.
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
1.0K
Multimachine Stability01:25

Multimachine Stability

Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
586