Related Experiment Video
Updated: Feb 15, 2026

Echocardiographic Characterization of Left Ventricular Structure, Function, and Coronary Flow in Neonate Mice
Published on: April 7, 2022
Characterizing left ventricular mechanical and electrical activation in patients with normal and impaired systolic
Christopher Piorkowski1, Arash Arya2, Craig D Markovitz3
1Department of Invasive Electrophysiology, University of Dresden-Heart Center, Dresden, Germany. Christopher.Piorkowski@herzzentrum-dresden.com.
Purpose:
Cardiac disease frequently has a degenerative effect on cardiac pump function and regional myocardial contraction. Therefore, an accurate assessment of regional wall motion is a measure of the extent and severity of the disease. We sought to further validate an intra-operative, sensor-based technology for measuring wall motion and strain by characterizing left ventricular (LV) mechanical and electrical activation patterns in patients with normal (NSF) and impaired systolic function (ISF).
Methods:
NSF (n = 10; ejection fraction = 62.9 ± 6.1%) and ISF (n = 18; ejection fraction = 35.1 ± 13.6%) patients underwent simultaneous electrical and motion mapping of the LV endocardium using electroanatomical mapping and navigational systems (EnSite™ NavX™ and MediGuide™, Abbott). Motion trajectories, strain profiles, and activation times were calculated over the six standard LV walls.
Results:
NSF patients had significantly greater motion and systolic strains across all LV walls than ISF patients. LV walls with low-voltage areas showed less motion and systolic strain than walls with normal voltage. LV electrical dyssynchrony was significantly smaller in NSF and ISF patients with narrow-QRS complexes than ISF patients with wide-QRS complexes, but mechanical dyssynchrony was larger in all ISF patients than NSF patients. The latest mechanical activation was most often the lateral/posterior walls in NSF and wide-QRS ISF patients but varied in narrow-QRS ISF patients.
Conclusions:
This intra-operative technique can be used to characterize LV wall motion and strain in patients with impaired systolic function. This technique may be utilized clinically to provide individually tailored LV lead positioning at the region of latest mechanical activation for patients undergoing cardiac resynchronization therapy.
Clinical Trial Registration:
URL: http://www.clinicaltrials.gov . Unique identifier: NCT01629160.
More Related Videos
Related Concept Videos
Mechanical Protein Functions
Mechanical Protein Function
Overview of the Cardiovascular System
Heart
The heart is the central pump of the cardiovascular system that circulates blood throughout the body. It comprises two atria receiving the blood and two ventricles pumping blood out of the heart. Their rhythmic contractions, called heartbeats, ensure that blood flow remains continuous.
Blood Vessels
Blood...
Reaction Mechanisms
For instance, the decomposition of ozone appears to follow a mechanism with two steps:
Normal Distribution
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...

