Related Experiment Video
Updated: Feb 15, 2026

A Method for Quantifying Upper Limb Performance in Daily Life Using Accelerometers
Published on: April 21, 2017
Reliability and Validity of a Medicine Ball-Contained Accelerometer for Measuring Upper-Body Neuromuscular
Gregory Roe1,2, William Shaw1, Joshua Darrall-Jones1,2
1Institute for Sport, Physical Activity and Leisure, Leeds Beckett University, Leeds, United Kingdom.
Abstract:
Roe, G, Shaw, W, Darrall-Jones, J, Phibbs, PJ, Read, D, Weakley, JJ, Till, K, and Jones, B. Reliability and validity of a medicine ball-contained accelerometer for measuring upper-body neuromuscular performance. J Strength Cond Res 32(7): 1915-1918, 2018-The aim of the study was to assess the between-day reliability and validity of a medicine ball-contained accelerometer (MBA) for assessing upper-body neuromuscular performance during a throwing task. Ten professional rugby union players partook in the study. Between-day reliability was assessed from the best score attained during 2 sets of 3 throws, on 2 testing occasions separated by 7 days. Validity was assessed against a criterion measure (Optioelectronic system) during 75 throws from a subgroup of 3 participants. The MBA exhibited a small between-day error of 2.2% (90% confidence intervals; 2.0-4.6%) and an almost perfect relationship with a criterion measure (r = 0.91 [90% CIs; 0.87-0.94]). However, the mean bias and standard error were moderate (7.9% [90% CIs; 6.6-9.2%] and 4.9% [90% CIs; 4.2-5.7%], respectively). Practitioners using an MBA to assess neuromuscular performance of the upper body must take into account the overestimation and error associated with such assessment with respect to a criterion measure. However, as the error associated with between-day testing was small and testing is easy to implement in applied practice, an MBA may provide a useful tool for monitoring upper-body neuromuscular performance over time.
Related Concept Videos
Reliability and Validity
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Distribution Reliability and Automation
The Neuromuscular Junction
Arteries of the Upper Limbs
Data Validation
Key parameters for method validation include:

