Complication Severity Score for Growth-friendly Surgery Has Strong Interrater and Intrarater Agreement

Nicole Michael1, Claire Palmer2, John T Smith3

  • 1Children's Hospital Colorado.

Insights

The Complication Severity Score for growth-friendly surgery demonstrates strong reliability among raters. This validated system standardizes complication reporting for growing spine surgery, improving research consistency.

Area of Science:

  • Spine Surgery
  • Orthopedic Research
  • Surgical Complications

Background:

  • Growth-friendly surgery techniques for early onset scoliosis are advancing rapidly.
  • High complication rates necessitate standardized reporting methods.
  • A Complication Severity Score was developed to ensure consistency in research.

Purpose of the Study:

  • To evaluate the interrater and intrarater reliability of the Complication Severity Score for growth-friendly surgery.
  • To determine if the classification system is a dependable tool for reporting surgical complications.

Main Methods:

  • A random sample of 63 early onset scoliosis cases was selected from a prospectively collected database.
  • An internet survey was administered to 20 faculty and research coordinators involved in early onset scoliosis research, twice over 3 weeks.
  • Fleiss Kappa and Cohen Kappa statistics were used to assess interrater and intrarater agreement, respectively.

Main Results:

  • Overall interrater agreement (Fleiss Kappa) was substantial at 0.86.
  • Almost perfect agreement was observed for most complication categories (e.g., Disease I: 0.91, Device IIB: 0.92).
  • Intrarater agreement was also high, with an overall Cohen Kappa of 0.86.

Conclusions:

  • The Complication Severity Score exhibits strong interrater and intrarater reliability.
  • The classification system is a reliable tool for standardizing complication reports in growth-friendly surgery.
  • Adoption of this system is recommended to enable consistent comparison of complications across different treatment modalities.
Abstract

Related Concept Videos

Titration Calculations: Strong Acid - Strong Base02:28

Titration Calculations: Strong Acid - Strong Base

Calculating pH for Titration Solutions: Strong Acid/Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
34.2K
Strong Acid and Base Solutions03:22

Strong Acid and Base Solutions

A strong acid is a compound that dissociates completely in an aqueous solution and produces a concentration of hydronium ions equal to the initial concentration of acid. For example, 0.20 M hydrobromic acid will dissociate completely in water and produces 0.20 M of hydronium ions and 0.20 M of bromide ions.
36.2K
Titration of a Strong Acid with a Strong Base01:23

Titration of a Strong Acid with a Strong Base

During the titration of a strong acid with a strong base, pH calculations are primarily based on the concentration of residual hydronium or hydroxide ions. Initially, a strong acid like hydrochloric acid fully dissociates, creating hydronium and chloride ions, resulting in a low pH. The addition of a strong base like sodium hydroxide alters the concentration of hydronium ions by neutralizing them. As more base is added, the pH gradually increases. At the equivalence point, all hydronium ions...
10.6K
Introduction to z Scores01:06

Introduction to z Scores

A z score (or standardized value) is measured in units of the standard deviation. It tells you how many standard deviations the value x is above (to the right of) or below (to the left of) the mean, μ. Values of x that are larger than the mean have positive z scores, and values of x that are smaller than the mean have negative z scores. If x equals the mean, then x has a zero z score. It is important to note that the mean of the z scores is zero, and the standard deviation is one.
z scores...
11.3K
Introduction to z Scores01:05

Introduction to z Scores

A z score (or standardized value) is measured in units of the standard deviation. It indicates how many standard deviations the value x is above (to the right of) or below (to the left of) the mean, μ. Values of x that are larger than the mean have positive z scores, and values of x that are smaller than the mean have negative z scores. If x equals the mean, then x has a zero z score. It is important to note that the mean of the z scores is zero, and the standard deviation is one.
z scores...
1.4K
z Scores and Area Under the Curve01:17

z Scores and Area Under the Curve

z scores are the standardized values obtained after converting a normal distribution into a standard normal distribution. A z score is measured in units of the standard deviation. The z score tells you how many standard deviations the value x is above (to the right of) or below (to the left of) the mean, μ. Values of x that are larger than the mean have positive z scores, and values of x that are smaller than the mean have negative z scores. If x equals the mean, then x has a z score of...
19.7K