Novel contrast mixture achieves contrast resolution of human bladder wall suitable for T1 mapping: applications in
Pradeep Tyagi1, Joseph Janicki2, Chan-Hong Moon3
1Department of Urology, University of Pittsburgh, E313 Montefiore Hospital, 3459 Fifth Ave, Pittsburgh, PA, 15213, USA. tyagip@upmc.edu.
Purpose:
Instillation of novel contrast mixture (NCM) was recently shown to improve the contrast resolution of rat bladder wall with high contrast-to-noise ratio (CNR). Here, the clinical safety and the feasibility of NCM-enhanced MRI to achieve artifact-free visualization of human bladder wall suitable for quantitative measurement of the magnetic resonance (MR) longitudinal relaxation time (T1) was assessed.
Methods:
Six female subjects [two controls and two with Hunner-type interstitial cystitis IC and two with non-Hunner-type IC] consented for MRI at 3 T before and after instillation of NCM [4 mM gadobutrol and 5 mM ferumoxytol in 50 mL of sterile water for injection]. Single breath-hold fast MR acquisition in large readout bandwidth for 5-mm-thick single slice with variable flip angle was applied to minimize the motion and chemical shift artifacts in measurements of bladder wall thickness (BWT), CNR and T1 from 20 pixels.
Results:
NCM instillation in subjects did not evoke pain or discomfort. Fourfold increase in bladder wall CNR (*p < 0.02) and pixel size of 0.35 mm with minimal influence of artifacts allowed accurate determination of bladder wall thinning ~ 0.46 mm from 50 mL NCM (*p < 0.05). Pre-contrast bladder wall T1 of 1544 ± 34.2 ms was shortened to 860.09 ± 13.95 ms in Hunner-type IC (*p < 0.0001) relative to only 1257.42 ± 20.59 and 1258.16 ± 6.16 ms in non-Hunner-type IC and controls, respectively.
Conclusion:
Findings demonstrate the safety and feasibility of NCM-enhanced MRI to achieve artifact-free differential contrast and spatial resolution of human bladder wall, which is suitable for measuring BWT and pixel-wise measurement of T1 in post-contrast setting.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Racemic Mixtures and the Resolution of Enantiomers
Mixtures of Acids
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
Mixtures of Acids
In a strong and weak acid mixture, the strong acid dissociates completely and becomes a source of almost all the hydronium ions present in the solution. In contrast, the weak acid shows...
Plant Cell Wall
Urinary Bladder
In males, the bladder is situated in front of the rectum, while in females, it is positioned anterior to the vagina and uterus. The bladder floor contains an inverted triangular area called the trigone, defined by the two ureteric...