Related Experiment Video
Updated: Feb 15, 2026

Exfoliation and Analysis of Large-area, Air-Sensitive Two-Dimensional Materials
Published on: January 5, 2019
Comparison of crop yield sensitivity to ozone between open-top chamber and free-air experiments
Zhaozhong Feng1,2, Johan Uddling3, Haoye Tang4
1State Key Laboratory of Urban and Regional Ecology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, China.
Abstract:
Assessments of the impacts of ozone (O3 ) on regional and global food production are currently based on results from experiments using open-top chambers (OTCs). However, there are concerns that these impact estimates might be biased due to the environmental artifacts imposed by this enclosure system. In this study, we collated O3 exposure and yield data for three major crop species-wheat, rice, and soybean-for which O3 experiments have been conducted with OTCs as well as the ecologically more realistic free-air O3 elevation (O3 -FACE) exposure system; both within the same cultivation region and country. For all three crops, we found that the sensitivity of crop yield to the O3 metric AOT40 (accumulated hourly O3 exposure above a cut-off threshold concentration of 40 ppb) significantly differed between OTC and O3 -FACE experiments. In wheat and rice, O3 sensitivity was higher in O3 -FACE than OTC experiments, while the opposite was the case for soybean. In all three crops, these differences could be linked to factors influencing stomatal conductance (manipulation of water inputs, passive chamber warming, and cultivar differences in gas exchange). Our study thus highlights the importance of accounting for factors that control stomatal O3 flux when applying experimental data to assess O3 impacts on crops at large spatial scales.
Related Concept Videos
Reaction Yield
ATP Yield
The ETC is embedded in the inner mitochondrial membrane and is comprised of four main protein complexes and an ATP synthase. NADH and FADH2 pass electrons to these complexes, which pump protons into the intermembrane space. This distribution of...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Chambers of the Heart
Deoxygenated blood from the body is received in the right...
What is an Experiment?
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...

