Related Experiment Video
Updated: Feb 15, 2026

Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
Resolving Apparent Inconsistencies Between Area, Flow, and Gradient Measurements in Patients With Aortic Valve
Yujing Mo1, Martin Penicka2, Giuseppe Di Gioia3
1Cardiovascular Center Aalst, OLV Clinic Aalst, Belgium; Department of Cardiology, Guangdong General Hospital, Guangzhou, China.
Abstract:
Inconsistencies between area (aortic valve area [AVA])-flow-gradient are common during the echocardiographic assessment of aortic stenosis (AS). This study was conducted to investigate the importance of these inconsistencies and the impact of 3 methods to resolve these inconsistencies. The study population consisted of 327 patients (age: 76.3 ± 8.6 years, 49.5% males) with severe AS (SAS) (AVA ≤ 1 cm2) and preserved left ventricular ejection fraction (≥50%). Inconsistent findings between AVA, flow, and mean gradient (MG) were observed in 78 (23.9%) patients with low flow and a high MG, 52 (15.9%) patients with normal flow and a low MG, and 37 (11.3%) patients with a low flow and a low MG. Using stroke volume index by catheterization for AVA recalculation showed the greatest effect to resolve inconsistencies in the low flow and a high MG group (85%). Decreasing the AVA cut-off values for SAS to ≤0.8 cm2 resulted in a shift from SAS to moderate AS in 36 patients (69%) in the normal flow and a low MG. Indexing AVA to body surface area had only a minor impact on reclassification. In conclusion, in patients with SAS and preserved left ventricular ejection fraction, the majority of area-flow-gradient inconsistencies at echocardiography can be resolved by correcting errors in stroke volume index measurements by alternative techniques and by redefining the cut-off value for SAS to ≤0.8 cm2.
Related Concept Videos
Apparent Weight
Consider a person standing on a bathroom scale inside an elevator. If the scale is accurate at rest, its reading equals the...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Apparent Weight and the Earth's Rotation
For an object on the Earth's equator, the net centripetal force that accounts for its rotation is the Earth's pull towards its center, or the weight minus the normal force that prevents it from piercing into the Earth's surface....
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Stenosis I: Introduction
Subcellular Fractionation
Differential Centrifugation
Differential centrifugation is...

