Abstract:
Recently, On-Board Imager (OBI) and ExacTrac x-ray 6 degree-of-freedom system (ExacTrac) are increasingly used verification systems in local radiotherapy centers. This study aimed to compare the differences between these two systems in terms of verification accuracy, organ doses, and verification time for head-and-neck (H&N) and pelvic cases. Rando anthropomorphic phantoms of H&N and pelvic regions were positioned with known set-up deviations from the reference position in the linear accelerator. x-Ray verification images were then acquired using both systems. Verification accuracy was evaluated based on the residual positioning error (δD) after image registration. Thermoluminescence dose meters (TLD-100s) were placed in specific locations of the phantoms for the measurement of imaging doses at the organs of interest. Besides, the verification time was also recorded for comparison. Most average detection errors for both systems were within 1 mm. The detection error of ExacTrac was significantly larger than OBI in the H&N region in all directions (p < 0.05), but was significantly lower in the pelvis (p < 0.05). The mean imaging doses to all organs of interest from ExacTrac were significantly lower than OBI (p < 0.05). The mean verification time for ExacTrac was about 10 seconds, which was significantly shorter than the 100 seconds in OBI (p < 0.001). Both verification systems achieved satisfactory performance in the H&N and pelvic regions despite ExacTrac being better in terms of verification time and organ dose. The verification accuracy of Exactrac was better in pelvic region than the H&N region when compared with OBI.
Related Concept Videos
Biological Effects of Radiation
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Self-Evaluation: Self-Enhancement and Self-Verification
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Strategies of Self-Presentation II: Self-Verification