Related Experiment Video
Updated: Feb 15, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Feasibility of a streamlined imaging protocol in technetium-99m-Tektrotyd somatostatin receptor SPECT/CT
H Al-Chalabi1, A Cook2, C Ellis2
1Department of Clinical Radiology, St James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK; Department of Nuclear Medicine, Level 1, Bexley Wing, St James's University Hospital, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
Aim:
To assess the feasibility and efficacy of a streamlined single time-point 99mTc-HYNIC-Tyr3-octreotide (Tektrotyd) somatostatin receptor scintigraphy (SRS) protocol to differentiate pathological uptake by neuroendocrine tumours (NETs) from physiological activity.
Methods And Materials:
Tektrotyd imaging in 50 consecutive patients with NETs was reviewed retrospectively. Imaging was independently assessed by two experienced reporters with dual-certification in radiology and nuclear medicine and agreed in consensus. The presence of physiological bowel activity and/or further sites of equivocal uptake on 4-hour planar imaging and whether combined single-photon-emission computed tomography (SPECT)/computed tomography (CT) assessment allowed accurate diagnosis was tabulated. A judgement was also made in each case on whether 2-hour planar imaging was necessary for accurate diagnostic interpretation.
Results:
Thirty-six patients (72%) had positive findings on Tektrotyd SPECT/CT. Eight patients (16%) had bowel activity on 4-hour planar imaging, which could be considered to have hampered interpretation without access to SPECT/CT. Eleven studies in 10 patients (20%) demonstrated areas of indeterminate uptake on planar imaging; five in the uncinate process of the pancreas, three in the nasal cavity or paranasal sinuses, one in the adrenal glands, one in a focus of inflammation on the posterior abdominal wall, and one at the tip of a central venous line. In all cases, accurate interpretation of findings was possible with SPECT/CT, without the 2-hour planar image.
Conclusion:
Two-hour planar imaging could be safely omitted from Tektrotyd SRS incorporating SPECT/CT imaging without reducing the accuracy of diagnostic interpretation. Streamlined imaging has the potential to reduce patient inconvenience and improve scanner and staff efficiency.
More Related Videos
10:54Preparation and Evaluation of 99mTc-labeled Tridentate Chelates for Pre-targeting Using Bioorthogonal Chemistry
Published on: February 4, 2017
07:52In Vivo Imaging and Tracking of Technetium-99m Labeled Bone Marrow Mesenchymal Stem Cells in Equine Tendinopathy
Published on: December 9, 2015
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Streamlines, Streaklines, and Pathlines
Bernoulli's Equation for Flow Along a Streamline
Internal Receptors