Related Experiment Video
Updated: Feb 15, 2026

Design of a Biocompatible Drug-Eluting Tracheal Stent in Mice with Laryngotracheal Stenosis
Published on: January 21, 2020
Transradial experience with bioresorbable vascular scaffolds: A case-matched study with metallic drug-eluting stents
Frédéric Maes1, Olivier Costerousse1, Tomas Cieza1
1Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, Canada.
Background:
Whether polymeric bioresorbable vascular scaffolds (BVS) implantation with transradial approach is feasible and safe is unknown. We compared the feasibility and safety of the transradial approach for BVS delivery with metallic drug-eluting stents (DES).
Methods:
We identified 118 consecutive patients who underwent BVS implantation and we compared 30-days and 1-year results with 118 matched patients with DES. Patients were matched for age, sex, risk factors and clinical indication.
Results:
Rates of transradial approach were 98% in the BVS group vs 95% in the DES group (P = 0.16) with 5Fr used in 38% and 32% (P = 0.34), respectively. The number of stents was similar in both groups, 2.6 ± 1.5 vs 2.4 ± 1.3 (P = 0.23). Although maximal pressure for stent deployment was identical in both groups (16 ± 3 atm), more lesions were pre-dilated (83% vs 52%, P < 0.001) and post-dilated (71% vs 33%, P < 0.001) in the BVS group. Contrast volume (217 ± 97 vs 175 ± 108 ml, P < 0.001), fluoroscopy time (16 [10-23] vs 13 [8-21] min, P = 0.04) and procedure duration (65 ± 31 vs 56 ± 47 min, P = 0.045) were significantly higher in the BVS group. Major adverse cardiac events, including death, myocardial infarction and target vessel revascularization remained similar in both groups, 1.7% vs 0.8% (P = 0.56) at 30 days and 10% vs 8.5% (P = 0.66) at 1 year. At 1 year, stent thrombosis occurred in 2 (1.7%) patients in the BVS group and 1 (0.8%) patient in the DES group (P = 0.56).
Conclusion:
The use of transradial approach for BVS compared to DES implantation was feasible and safe in all-comers, although BVS implantation included more technical challenges. Outcomes up to 1-year remained comparable in both groups.
More Related Videos
12:30Vascular Gene Transfer from Metallic Stent Surfaces Using Adenoviral Vectors Tethered through Hydrolysable Cross-linkers
Published on: August 12, 2014
06:55Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
Related Concept Videos
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Alkali Metals
Table 1: Properties of the alkali metals
Imaging Studies VII: Vascular Imaging
High-Performance Liquid Chromatography: Elution Process