Related Experiment Video
Updated: Feb 15, 2026

Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
Subaxillary approach to cardiac electronic device implantation using a single surgical incision: a single-centre
Bruna Bolzan1, Martina Morosato2, Domenico Caponi3
1Department of Cardiology, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy.
Objectives:
Pacemakers and implantable cardioverter defibrillators have become more common in younger individuals, owing to broader indications and technological advances. Our goal was to report our long-term experience of implanting cardiac devices in young adults via a subaxillary approach with a hidden single incision, to minimize the aesthetic impact of the device.
Methods:
From 2003 to 2012, 23 patients underwent cardiac device implantation via a subaxillary approach while they were under general anaesthesia. The axillary vein was punctured under contrast-medium radiological guidance. The devices were positioned into the pocket under the pectoralis major muscle and over the fascia that envelopes the pectoralis minor muscle, through a lateral surgical access along the midaxillary line.
Results:
Twenty-two single- and dual-chamber implantable cardioverter defibrillator and 1 dual-chamber pacemaker were implanted (mean age 32.2 ± 13.4 years). All procedures were successfully performed without complications; overall hospitalization after implantation was 3.3 days. During mean a follow-up of 65 ± 18 months, no deaths, infections or device migrations occurred. Two ventricular lead dislodgements requiring repositioning occurred within 1 month, and 1 defibrillation lead fracture occurred 5 years after implantation. All patients were extremely satisfied with the aesthetic result. A mild increase in the pacing threshold (0.88 ± 0.6 V at 0.4/0.5 ms at implantation vs 1.00 ± 0.3 V at 0.4/0.5 ms at 2-year follow-up, P = 0.063) and a statistically significant decrease in the pacing impedance (637 ± 161 ohm at implantation vs 499 ± 81 ohm at 2-year follow-up, P = 0.001) were observed, without any consequences.
Conclusions:
The subaxillary approach is a safe, feasible technique that requires a simple surgical procedure. The implantable cardioverter defibrillator functions properly at implantation and at long-term follow-up.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
09:04Low-Cost Single-Port LoCoSP Device for a Transcervical Approach in Minimally Invasive Transhiatal Esophagectomy
Published on: September 11, 2021
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Angular Momentum: Single Particle
Single-pass Transmembrane Proteins
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...