Effect of insufficient temporal coherence on visibility contrast in X-ray grating interferometry
Abstract:
X-ray grating interferometry, which has been spotlighted in the last decade as a multi-modal X-ray imaging technique, can provide three independent images, i.e., absorption, differential-phase, and visibility-contrast images. We report on a cause of the visibility contrast, an effect of insufficient temporal coherence, that can be observed when continuous-spectrum X-rays are used. This effect occurs even for a sample without unresolvable random structures, which are known as the main causes of visibility contrast. We performed an experiment using an acrylic cylinder and quantitatively explained the visibility contrast due to this effect.
More Related Videos
07:02Author Spotlight: Advancements in In Vivo and Ex Vivo Retinal Imaging for Improved Glaucoma Diagnosis and Treatment
Published on: June 30, 2023
12:08Fabrication of High Contrast Gratings for the Spectrum Splitting Dispersive Element in a Concentrated Photovoltaic System
Published on: July 18, 2015
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Imaging
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...