Purpose:
To evaluate the performance of automated feeder detection (AFD) software (EmboGuide; Philips Healthcare, Best, The Netherlands) on hepatocellular carcinoma (HCC) tumors during transarterial chemoembolization.
Materials And Methods:
Forty-four first-time transarterial chemoembolization patients (37 men; mean age, 62 ± 11 years) were enrolled between May 2012 and July 2013. A total of 86 HCC lesions were treated (2.0 ± 1.4 lesions per patient; 27.6 ± 15.9 mm maximum diameter). One hundred forty-seven feeding arteries were found with digital subtraction angiography (DSA), cone-beam computed tomography (CT), and AFD software with the option of manual adjustment (MA). Three independent interventional radiologists analyzed the cone-beam CT images retrospectively with and without AFD and MA. Compared with the number of treated vessels, the number of true positives, false positives, false negatives, sensitivity, and interreader agreement were determined using clustered binary data analysis.
Results:
Cone-beam CT enabled detection of 100 ± 3.5 feeding arteries (70% sensitivity) with 68.6% agreement among readers. AFD software significantly improved detection to 127±0.6 feeding arteries (86% sensitivity, P = .008) with 99.7% reader agreement and reduced the number of false negatives from an average of 47 ± 3.5 to 20 ± 0.6 (P = .008). MA of the AFD results produced similar feeding artery detection rates (127 ± 5.1, 86% sensitivity, P = .8), with lower interreader agreement (91.6%) and slightly fewer false positives (16 ± 0.0 to 14 ± 2.5, P = .4).
Conclusions:
AFD software significantly improved feeding artery detection rates during transarterial chemoembolization of HCC lesions with better user reproducibility compared with cone-beam CT alone. In conjunction with DSA, AFD enables maximum feeding artery detection in this setting.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
Related Concept Videos
Enteral Nutrition I: Orogastric and Nasogastric Feeding
Orogastric (OG) and nasogastric (NG) feeding are two standard methods used for enteral nutrition. Enteral nutrition is often preferred over...
Enteral Nutrition II: Nasointestinal and Gastrostomy Feeding
Nasointestinal Feeding
Nasointestinal feeding involves placing a tube...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Statistical Software for Data Analysis and Clinical Trials
GIS Software, Hardware, and Sources of GIS Data
Arteries of Lower Limbs