Stability-indicating liquid chromatographic method for the determination of Letrozole in pharmaceutical formulations
M Mathrusri Annapurna1, Chitaranjan Mohapatro2, A Narendra2
1Department of Pharmaceutical Analysis & Quality Assurance, GITAM Institute of Pharmacy, GITAM University, Visakhapatnam 530045, India.
Abstract:
A stability-indicating high-performance liquid chromatographic method was developed and validated for the determination of Letrozole in tablet dosage forms. Reversed-phase chromatography was performed on Shimadzu Model LC-Class-Vp with Lichrocart/Lichrosphere 100 C-18 (250 mm×4.6 mm, 5 μm particle size) column with methanol: tetra butyl ammonium hydrogen sulfate (80:20V/V) as mobile phase at a flow rate of 1 mL/min with UV detection at 240 nm. Linearity was observed in the concentration range of 0.5-150 μg/mL (R2=0.9998) with regression equation y=102582x+43185. The limit of quantitation (LOQ) and limit of detection (LOD) were found to be 0.043 and 0.012 μg/mL respectively. The forced degradation studies were performed by using HCl, NaOH, H2O2, thermal and UV radiation. Letrozole is more sensitive towards alkaline conditions and very much resistant towards acidic, oxidative and photolytic degradations. The method was validated as per ICH guidelines. The RSD for intra-day (0.78-0.97) and inter-day (0.86-0.96) precision were found to be lesser than 1%. The percentage recovery was in good agreement with the labeled amount in the pharmaceutical formulations and the method is simple, specific, precise and accurate for the determination of Letrozole in pharmaceutical formulations.
Related Concept Videos
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Pharmaceutical Equivalents
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...