Cathodic adsorptive stripping voltammetry of an anti-emetic agent Granisetron in pharmaceutical formulation and

Rajeev Jain1, Ramkishor Sharma1

  • 1School of Studies in Chemistry, Jiwaji University, Gwalior 474011, India.

Related Concept Videos

Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
1.0K
Drugs for Treatment of Crohn's Disease in IBD Using Biologic Agents: Anti-TNF01:24

Drugs for Treatment of Crohn's Disease in IBD Using Biologic Agents: Anti-TNF

Tumor Necrosis Factor (TNF), a proinflammatory cytokine, contributes significantly to the inflammation seen in Crohn's disease. It exists as soluble TNF and membrane-bound TNF, with actions mediated through TNF receptors (TNFR). TNFR activation leads to the release of proinflammatory cytokines, T-cell activation, collagen production, and leukocyte migration, all contributing to inflammation in Crohn's disease. Anti-TNF monoclonal antibodies, namely infliximab (Remicade), adalimumab...
598
Pharmaceutical Equivalents01:26

Pharmaceutical Equivalents

As defined by regulatory standards, pharmaceutical equivalents require generic drug products to have identical dosage forms and chemically identical active pharmaceutical ingredients (APIs). They must adhere to compendial or applicable standards for potency, content uniformity, disintegration times, and dissolution rates. In the case of modified-release dosage forms, variations in drug content are permissible as long as the delivered amount remains consistent with the innovator drug product.
208
Voltammetry: Overview01:20

Voltammetry: Overview

Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
3.0K
Analyte Adsorption and Distribution01:09

Analyte Adsorption and Distribution

In certain chromatographic separations, solutes transfer between the mobile phase and the stationary phase via sorption, which typically refers to the process of adsorption. For many chromatographic systems, the sorption process often depends on the polarity of the compounds—an expression of the overall dipole moment within the molecule. During the separation process, there is competition between the solute and solvent for adsorption to the stationary phase. Highly polar compounds and...
2.8K
Voltammetry: Factors Affecting Measurements01:21

Voltammetry: Factors Affecting Measurements

A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
602