Selective micellar electrokinetic chromatographic method for simultaneous determination of some pharmaceutical binary
Michael E El-Kommos1, Niveen A Mohamed1, Ahmed F Abdel Hakiem1
1Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, Assiut 71526, Egypt.
Abstract:
A simple and selective micellar electrokinetic chromatographic (MEKC) method has been developed for the analysis of five pharmaceutical binary mixtures containing three non-steroidal anti-inflammatory drugs (NSAIDs). The investigated mixtures were Ibuprofen (IP)-Paracetamol (PC), Ibuprofen (IP)-Chlorzoxazone (CZ), Ibuprofen (IP)-Methocarbamol (MC), Ketoprofen (KP)-Chlorzoxazone (CZ) and Diclofenac sodium (DS)-Lidocaine hydrochloride (LC). The separation was run for all mixtures using borate buffer (20 mM, pH 9) containing 15% (v/v) methanol and 100 mM sodium dodecyl sulphate (SDS) at 15 kV and the components were detected at 214 nm. Different factors affecting the electrophoretic mobility of the seven investigated drugs were studied and optimized. The method was validated according to international conference of harmonization (ICH) guidelines and United States pharmacopoeia (USP). The method was applied to the analysis of five pharmaceutical binary mixtures in their dosage forms. The results were compared with other reported high performance liquid chromatographic methods and no significant differences were observed.
Related Concept Videos
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Mixtures of Acids
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...