Related Experiment Video
Updated: Feb 14, 2026

Quantitative Assessment of Cortical Auditory-tactile Processing in Children with Disabilities
Published on: January 29, 2014
Feasibility of 15O-water PET studies of auditory system activation during general anesthesia in children
Martin Mamach1,2,3, Florian Wilke3, Martin Durisin4
1Department of Nuclear Medicine, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany.
Background:
15O-Water positron emission tomography (PET) enables functional imaging of the auditory system during stimulation via a promontory electrode or cochlear implant, which is not possible using functional magnetic resonance imaging (fMRI). Although PET has been introduced in this context decades ago, its feasibility when performed during general anesthesia has not yet been explored. However, due to a shift to earlier (and bilateral) auditory implantation, the need to study children during general anesthesia appeared, since they are not able to cooperate during scanning. Therefore, we evaluated retrospectively results of individual SPM (statistical parametric mapping) analysis of 15O-water PET in 17 children studied during general anesthesia and compared them to those in 9 adults studied while awake. Specifically, the influence of scan duration, smoothing filter kernel employed during preprocessing, and cut-off value used for statistical inferences were evaluated. Frequencies, peak heights, and extents of activations in auditory and extra-auditory brain regions (AR and eAR) were registered.
Results:
It was possible to demonstrate activations in auditory brain regions during general anesthesia; however, the frequency and markedness of positive findings were dependent on some of the abovementioned influence factors. Scan duration (60 vs. 90 s) had no significant influence on peak height of auditory cortex activations. To achieve a similar frequency and extent of AR activations during general anesthesia compared to waking state, a lower cut-off for statistical inferences (p < 0.05 or p < 0.01 vs. p < 0.001) had to be applied. However, this lower cut-off was frequently associated with unexpected, "artificial" activations in eAR. These activations in eAR could be slightly reduced by the use of a stronger smoothing filter kernel during preprocessing of the data (e.g., [30 mm]3).
Conclusions:
Our data indicate that it is feasible to detect auditory cortex activations in 15O-water PET during general anesthesia. Combined with the improved signal to noise ratios of modern PET scanners, this suggests reasonable prospects for further evaluation of the method for clinical use in auditory implant users. Adapted parameters for data analysis seem to be helpful to improve the proportion of signals in AR versus eAR.
Related Concept Videos
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia
The Auditory Ossicles
The aptly named stapes look very much like a stirrup. The three ossicles are unique to mammals, and each plays a role in...
Auditory Perception
Auditory Pathway
When viewed cross-sectionally, the cochlea reveals the scala vestibuli and scala tympani flanking...
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...

