Related Experiment Video
Updated: Feb 14, 2026

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Additive Partial Least Squares for efficient modelling of independent variance sources demonstrated on practical case
Pekka Luoma1, Thomas Natschläger2, Birgit Malli2
1RECENDT - Research Center for Non-Destructive Testing, Altenbergerstrasse 69, Linz, Austria.
Abstract:
A model recalibration method based on additive Partial Least Squares (PLS) regression is generalized for multi-adjustment scenarios of independent variance sources (referred to as additive PLS - aPLS). aPLS allows for effortless model readjustment under changing measurement conditions and the combination of independent variance sources with the initial model by means of additive modelling. We demonstrate these distinguishing features on two NIR spectroscopic case-studies. In case study 1 aPLS was used as a readjustment method for an emerging offset. The achieved RMS error of prediction (1.91 a.u.) was of similar level as before the offset occurred (2.11 a.u.). In case-study 2 a calibration combining different variance sources was conducted. The achieved performance was of sufficient level with an absolute error being better than 0.8% of the mean concentration, therefore being able to compensate negative effects of two independent variance sources. The presented results show the applicability of the aPLS approach. The main advantages of the method are that the original model stays unadjusted and that the modelling is conducted on concrete changes in the spectra thus supporting efficient (in most cases straightforward) modelling. Additionally, the method is put into context of existing machine learning algorithms.
More Related Videos
08:08Using Wavelet Entropy to Demonstrate how Mindfulness Practice Increases Coordination between Irregular Cerebral and Cardiac Activities
Published on: May 10, 2017
06:33Decomposing the Variance in Reading Comprehension to Reveal the Unique and Common Effects of Language and Decoding
Published on: October 11, 2018
Related Concept Videos
Independent and Dependent Sources
Independent voltage or current sources supply a fixed amount of voltage or current, respectively, which is unaffected by other elements within the circuit. These are represented using specific symbols. Independent voltage sources are symbolized with polarities (+ and -), indicating the direction of the...
Variance
The standard deviation measures the spread in the same units as the data....
Punnett Squares
Introduction to Test of Independence
The test statistic for a test of independence is similar to that of a goodness-of-fit test:
Hypothesis Test for Test of Independence
H0: The two variables (factors)...
Conjugate Addition (1,4-Addition) vs Direct Addition (1,2-Addition)
Conjugate addition results in a thermodynamically stable product. The reaction retains the stronger C=O bond at the expense of the weaker C=C π bond. The process is slow as the β carbon is less electrophilic than the carbonyl carbon.
Direct addition products are...