Related Experiment Video
Updated: Feb 14, 2026

Author Spotlight: High-Quality Quantum Dot Nanobeads for Sensitive Fluorescent Lateral Flow Immunoassays
Published on: June 28, 2024
Double-enhanced lateral flow immunoassay for potato virus X based on a combination of magnetic and gold nanoparticles
Shyatesa C Razo1, Vasily G Panferov2, Irina V Safenkova2
1A.N. Bach Institute of Biochemistry, Research Centre of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia; Agricultural-Technological Institute, Peoples' Friendship University of Russia, Mikluho-Maklaya Street 8/2, 117198 Moscow, Russia.
Abstract:
This study presents the joint use of magnetic nanoparticles (MNPs) and gold nanoparticles (GNPs) for double enhancement in a lateral flow immunoassay (LFIA). The study realizes two types of enhancement: (1) increasing the concentration of analytes in the samples using conjugates of MNPs with specific antibodies and (2) increasing the visibility of the label through MNP aggregation caused by GNPs. The proposed strategy was implemented using a LFIA for potato virus X (PVX), a significant potato pathogen. MNPs conjugated with biotinylated antibodies specific to PVX and GNPs conjugated with streptavidin were synthesized and characterized. The LFIAs with and without the proposed enhancements were compared. The double-enhanced LFIA achieved the highest sensitivity, equal to 0.25 ng mL-1 and 32 times more sensitivity than the non-enhanced LFIA (detection limit: 8 ng mL-1). LFIAs using one of the types of amplification (magnetic concentration without GNPs-causing aggregation or MNP aggregation without the concentration stage) showed intermediate levels of sensitivity. The double-enhanced LFIA was successfully used for PVX detection in potato leaves. The results for PVX detection in the infected plants were similar for the double-enhanced LFIA developed and the conventional LFIA based on the GNP conjugates; however, the new system provided significant coloring enhancement. This study confirmed that a simple combination of MNPs and GNPs has great potential for high-sensitivity detection and could possibly be adopted for LFIAs of other compounds.
Related Concept Videos
What are Viruses?
Lateralization
Self-Evaluation: Self-Enhancement and Self-Verification
Fixing Double-strand Breaks
Gene Flow
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...

