Related Experiment Video
Updated: Feb 14, 2026

Hydroquinone Based Synthesis of Gold Nanorods
Published on: August 10, 2016
Gold Nanorod-Based Engineered Cardiac Patch for Suture-Free Engraftment by Near IR
Maayan Malki1,2, Sharon Fleischer2,3, Assaf Shapira2,3,4
1The Department of Materials Science and Engineering, Faculty of Engineering , Tel Aviv University , Tel Aviv 6997801 , Israel.
Abstract:
Although cardiac patches hold a promise for repairing the infarcted heart, their integration with the myocardium by sutures may cause further damage to the diseased organ. To address this issue, we developed facile and safe, suture-free technology for the attachment of engineered tissues to organs. Here, nanocomposite scaffolds comprised of albumin electrospun fibers and gold nanorods (AuNRs) were developed. Cardiac cells were seeded within the scaffolds and assembled into a functioning patch. The engineered tissue was then positioned on the myocardium and irradiated with a near IR laser (808 nm). The AuNRs were able to absorb the light and convert it to thermal energy, which locally changed the molecular structure of the fibrous scaffold, and strongly, but safely, attached it to the wall of the heart. Such hybrid biomaterials can be used in the future to integrate any engineered tissue with any defected organs, while minimizing the risk of additional injury for the patient, caused by the conventional stitching methods.
Related Concept Videos
Long-patch Base Excision Repair
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
What is Genetic Engineering?
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Heat Engines
Whenever we consider heat engines (and associated devices such as refrigerators and heat pumps), we do not use the standard sign convention for heat and work. For convenience, we assume that the symbols Qh, Qc, and W represent only the amounts of heat transferred...

