Related Experiment Video
Updated: Feb 14, 2026

Generation of Induced-pluripotent Stem Cells Using Fibroblast-like Synoviocytes Isolated from Joints of Rheumatoid Arthritis Patients
Published on: October 16, 2016
Acute phase reactant, Pentraxin 3, as a novel marker for the diagnosis of rheumatoid arthritis
1Department of Medicine, J N Medical College and Hospital, Aligarh Muslim University, Aligarh, India.
Introduction:
Pentraxins are a group of highly conserved acute-phase reactant proteins and play crucial role as modulators of inflammatory processes. Pentraxin 3 (PTX3) is primarily produced and released by vascular cell wall, hence, we attempt to establish the role of PTX3 as a biomarker for Rheumatoid Arthritis (RA) compared to CRP.
Methods:
Thirty patients having active RA as cases and 30 osteoarthritis (OA) patients as controls were recruited. Paired serum and synovial fluid samples were analysed for concentrations of both PTX3 and CRP by using high sensitivity ELISA kit and ROC curve was plotted.
Results:
Concentrations of PTX3 and CRP were significantly higher in RA patient serum (p < 0.0001) as well as in synovial fluid (p < 0.0001) and correlated with disease severity. Upon correlation analysis, positive correlation was found between serum and synovial fluid concentrations of PTX3 and CRP. The diagnostic potential of PTX3 was observed in synovial fluid while combination of PTX3 and CRP showed better sensitivity in serum.
Conclusion:
PTX3 found to be sensitive non-invasive indicator of clinical arthritic activity in RA patients when compared to traditional markers like CRP. Combination of PTX3 and CRP could serve as better differential diagnostic markers for RA after validation in larger patient cohort.
Related Concept Videos
Limiting Reactant
Phase Diagrams
Phase Transitions
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...

