Related Experiment Video
Updated: Feb 14, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Unilateral pedal lymphangiography plus computed tomography angiography for location of persistent idiopathic chyle
Dingyi Liu1, Boke Liu2, Weimu Xia3
1Department of Urology, Department of Radiology, Shanghai Punan Hospital, Shanghai, People's Republic of China.
Background:
To identify the value of unilateral pedal lymphangiography (LPG) plus computed tomography angiography (CTA) in accurate depiction of persistent idiopathic chyluria undetectable by ordinary contrast CT.
Methods:
Eighteen patients 44-63 years of age with persistent idiopathic chyluria who failed conservative management were included. Ordinary CT had not revealed a chyle leak. Cystoscopy, unilateral LPG, and post-LPG CT angiography (CTA) were sequentially performed. Ligation and stripping of the perirenal lymphatics were subsequently performed guided by lymphangiography and CTA.
Results:
LPG and post-LPG CTA detected 17 unilateral and one bilateral chyle leaks in the 18 patients, with clear images of the communication of lymphatic vessels and the renal collecting or vascular system. The success rate was significantly better than cystoscopy (100% vs 50.0%, P = 0.005) or LPG alone (100% vs. 72.2%, P = 0.016). Chyluria resolved after surgery in all patients; no relapses were found.
Conclusions:
LPG plus post-LPG CTA accurately characterized perirenal lymphangiectasia that was not demonstrated by routine contrast-enhanced CT or not suitable for magnetic resonance imaging. Despite of its invasiveness, this method is a good diagnostic alternative to LPG in patients with persistent chyluria requiring surgery.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Design Example: Traverse Angle Computations
Area Computation by the Alternative Coordinate Method
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....

