Related Experiment Video
Updated: Feb 14, 2026

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Quantitative analysis in peritumoral volumes of brain metastases treated with stereotactic radiotherapy
Min Soo Kim1, Sung Ho Park1, Eun Suk Park1
1Department of Neurosurgery, Ulsan University Hospital, University of Ulsan College of Medicine, 877, Bangeojin sunhwando-ro, Dong-gu, 44033 Ulsan, Republic of Korea.
Purpose:
The purpose of this study was to verify changes in diffusion tensor imaging (DTI) factors in patients with brain metastases treated with stereotactic radiotherapy (SRT). We also investigated the impact of SRT on peritumoral volumes though the use of DTI.
Methods:
A total of 28 patients with brain metastases who had undergone SRT between March 2014 and December 2015 were enrolled. Magnetic resonance imaging with DTI factors, such as fractional anisotropy (FA) and apparent diffusion tensor (ADC) value, was performed 1 day before the procedure and 3 months after the procedure. DTI data from tumor lesions, edema volumes, and the volumes that received 12Gy were measured.
Results:
Tumor volume (P=0.001) and ADC values in the volumes that received 12Gy (P=0.018) and the edema volumes (P=0.003) significantly decreased after the procedure. Decreases in tumor volume were only correlated with decreases in edema volumes (P<0.001). Decreases in edema volumes were correlated with increases in FA values and decreases in ADC values of the volumes that received 12Gy [P=0.019 (FA)/0.002 (ADC)] and the edema volumes [P=0.011 (FA)/0.002 (ADC)].
Conclusions:
It was possible to quantify changes in peritumoral volumes in patients with brain metastases after SRT by using DTI. ADC values of peritumoral volumes decreased significantly after SRT. Therefore, it was confirmed through DTI that performing SRT on tumor lesions has a positive effect on the structure and function of peritumoral volumes.
Related Concept Videos
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
Constant Volume Calorimetry
Volume of Distribution
Problem Solving: Volume
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Work Done During Volume Change
Consider a gas confined to a cylinder fitted with a movable piston at one end. If the gas expands from volume V1 to volume V2, it exerts a force on the piston, such that the piston moves by a distance dr.
The work done by the gas on the piston can be expressed as

