Related Experiment Video
Updated: Feb 14, 2026

Isolation and Characterization of the Murine Uterosacral Ligaments and Pelvic Floor Organs
Published on: March 3, 2023
Prospective evaluation of the safety and feasibility of a pelvic floor dilator during active labor
Francisco J Orejuela1, Rajshi Gandhi2, Lauren Mack2
1Department of Obstetrics and Gynecology, Baylor College of Medicine and Texas Children's Hospital Pavilion for Women, 6651 Main Street, Houston, TX, 77030, USA. orejuela@bcm.edu.
Introduction And Hypothesis:
The objective was to assess the safety and feasibility of using a pelvic floor dilator during active labor to prevent injuries to the levator ani muscle (LAM) and perineum.
Methods:
In a prospective pilot study, a pelvic floor dilator using soft pads was introduced into the vaginal canal to gradually expand the vagina, in 30 nulliparous women and in 10 controls. The primary outcomes were adverse events related to the device. Secondary outcomes were perineal lacerations after delivery, sonographically defined levator ani injury, hiatal area dimensions, and anal sphincter disruption, all at 12-20 weeks postpartum, and maximum pelvic floor dilation, time to achieve maximum dilation, and device retention rate.
Results:
From October 2014 through November 2016, a total of 494 women were screened, and 61 consented to the study. Thirty women used the device and 27 returned for follow-up. No maternal or neonatal injuries were related to use of the dilator. The average maximum dilation of the vaginal canal was 7.4 cm (SD 0.7, range 5.5-8.0). Dilation time averaged 27 min (SD 13, range 5-60). Device insertion adjustment was needed in 13 out of 30 cases (43%). Similar rates of 3th-4th degree perineal lacerations were seen in both groups. Levator ani avulsion was diagnosed in 2 out of 27 (7%) in the device group and in 1 out of 9 (11%) in the control group (p = 0.2). The rate of partial injury in the device group was 2 out of 27 (7%) vs 2 out of 9 (22%) in the comparison group (p = 0.2).
Conclusion:
The use of the pelvic floor dilator during active labor is feasible. No safety issues were identified.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
11:15Automated Visual Cognitive Tasks for Recording Neural Activity Using a Floor Projection Maze
Published on: February 20, 2014
Related Concept Videos
Muscles of the Pelvic Floor and Perineum
Perineal Layer
The perineum is a diamond-shaped area below the pelvic diaphragm, divided into an anterior urogenital triangle that contains the external genitals and a posterior anal triangle housing the anus. The urogenital...
Survey Safety
Cardiomyopathy II: Dilated Cardiomyopathy
Household Wiring And Electrical Safety
Self-Evaluation: Self-Enhancement and Self-Verification
Co-activators and Co-repressors