Related Experiment Video
Updated: Feb 14, 2026

Skeletal Muscle Gender Dimorphism from Proteomics
Published on: December 14, 2011
Gender differences and demographics and type of cardiac device over a 10-year period
M Aktoz1, M F Uçar1, M A Yılmaztepe1
1Department of Cardiology, School of Medicine, Trakya University, Edirne, Turkey.
Aims:
This study aims to review the influence of gender-specific differences and patient demographics on cardiac device and pacing mode selection over a 10-year period.
Methods:
We retrospectively reviewed patients who underwent first implantation of the cardiac device between January 1, 2006 and June 31, 2016.
Results:
During the study period, 704 patients underwent first cardiac device implantation. Number of patients undergoing pacemaker was 452 and number of patients undergoing implantable cardioverter defibrillator/cardiac resynchronization therapy and defibrillator (ICD/CRT-D) was 252. Patients undergoing pacemaker were 49.9% female with mean age 72.36+11.1. The most common indication was atrioventricular block (AVB) (84%) in both genders. The most frequently used pacing modes were VVI (70.8%), but over a 10-year period pacemaker selection shifted from VVI to DDD pacemakers. Patients undergoing ICD/CRT-D were 19.7% female with mean age 62.5+10.8. The most common indications for ICD/CRT-D was ischemic cardiomyopathy (ICMP) (55.0%). The rate of male patients was higher in patients who have received device therapy for dilated cardiomyopathy (DCMP) or ICMP, whereas the rate of female patients was higher in hypertrophic cardiomyopathy (HCMP) patients. The most common used implanted system was VVI-ICD (60.6%).
Conclusions:
The present study demonstrated that there was no significant difference between female and male patients in pacing mode selection, mostly VVI pacing mode was chosen; however, over a 10-year period pacemaker selection shifted from VVI to DDD pacemakers. Female patients had less ICD/CRT-D implantation than male patients.
Related Concept Videos
The Periodic Table
Socioemotional Experience and Gender Development
Periodic Classification of the Elements
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
The Periodic Table and Organismal Elements
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...