Related Experiment Video
Updated: Feb 14, 2026

Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
Published on: October 20, 2010
Quantification of Radiation Exposure of Non-Dominant Index for the Surgeon Performing Sentinel Lymph-Node Removal
Claudiu Peştean1,2, Maria Iulia Larg1,2, Elena Bărbuş1,2
1Department of Nuclear Medicine, Ion Chiricuta Institute of Oncology, Cluj-Napoca, Romania.
Background:
Sentinel lymph-node scintigraphy is a useful method for accurate staging of different tumors and a helpful tool in personalized therapy for oncological patients. The radiation exposure for surgical staff has been a concern since the sentinel lymph-node detection method was developed.
Objective:
The objective of the study was to determine and quantify the exposure to radiation of the non-dominant index for the surgeon performing sentinel lymph-node removal and to determine, if there is an irradiation risk imposed during the surgical procedure.
Method:
We performed a study over a period of one year, where we evaluated the exposure of surgeon's non-dominant index during 196 sentinel lymph-node removal procedures. The pharmaceutical was administrated via subcutaneous injection in four peritumoral or perilesional injection sites. The equipment we used consisted of EuroProbe3 for sentinel lymph-node detection and ring TLD dosimeter placed on the surgeon's non-dominant index.
Results:
The clinical distribution was: 104 melanomas, 84 breast carcinomas, 6 vulvar carcinomas and 2 penial carcinomas. The administered activity showed an average of 39.55 MBq (SD ± 1.96) Tc-99m nanoalbumin compound. The non-dominant index exposure ranged between 0.10 mSv and 0.13 mSv/month with a cumulative dose of 1.31 mSv/year, thus 6.69 µSv per procedure.
Conclusion:
The surgeon received a minimal dose for the non-dominant index. The values we recorded did not pose any additional concerns or restrictions, the exposure being under the limits and constraints established by regulations, close to the detectability limit of the dosimeter. The procedure is safe in terms of radiation protection, respecting the limitation and optimization principles.
Related Concept Videos
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...
Biological Effects of Radiation
Incomplete Dominance
Radiation: Applications
The average...
Absorption of Radiation
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...