Related Experiment Video
Updated: Feb 14, 2026

Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Diagnostic performance of different perfusion algorithms for the detection of angiographical spasm
Saif Afat1, Carolin Brockmann2, Omid Nikoubashman3
1Department of Diagnostic and Interventional Neuroradiology, RWTH Aachen University, 52074 Aachen, Germany.
Purpose:
To assess the diagnostic utility of different perfusion algorithms for the detection of angiographical terial spasm.
Method:
During a 2-year period, 45 datasets from 29 patients (54.2±10,75y, 20F) with suspected cerebral vasospasm after aneurysmal subarachnoid hemorrhage were included. Volume Perfusion CT (VPCT), Non-enhanced CT (NCT) and angiography were performed within 6hours post-ictus. Perfusion maps were generated using a maximum slope (MS) and a deconvolution-based approach (DC). Two blinded neuroradiologists independently evaluated MS and DC maps regarding vasospasm-related perfusion impairment on a 3-point Likert-scale (0=no impairment, 1=impairment affecting <50%, 2=impairment affecting >50% of vascular territory). A third independent neuroradiologist assessed angiography for presence and severity of arterial narrowing on a 3-point Likert scale (0=no narrowing, 1=narrowing affecting <50%, 2=narrowing affecting>50% of artery diameter). MS and DC perfusion maps were evaluated regarding diagnostic accuracy for angiographical arterial spasm with angiography as reference standard. Correlation analysis of angiography findings with both MS and DC perfusion maps was additionally performed. Furthermor, the agreement between MS and DC and inter-reader agreement was assessed.
Results:
DC maps yielded significantly higher diagnostic accuracy than MS perfusion maps (DC:AUC=.870; MS:AUC=.805; P=0.007) with higher sensitivity for DC compared to MS (DC:sensitivity=.758; MS:sensitivity=.625). DC maps revealed stronger correlation with angiography than MS (DC: R=.788; MS: R=694;=<0.001). MS and DC showed substantial agreement (Kappa=.626). Regarding inter-reader analysis, (almost) perfect inter-reader agreement was observed for both MS and DC maps (Kappa≥981).
Conclusion:
DC yields significantly higher diagnostic accuracy for the detection of angiographic arterial spasm and higher correlation with angiographic findings compared to MS.
Related Concept Videos
Vascular Spasm
Trial and Error and Algorithm
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:

