Plate Alone Versus Plate and Lag Screw for Lapidus Arthrodesis: A Biomechanical Comparison of Compression
Peter Kameel Garas1, Steven Thomas DiSegna1, Abhay R Patel1
1Department of Orthopedics, University of Massachusetts Memorial Medical Center, Worcester, Massachusetts.
Abstract:
Background. Arthrodesis of the first tarsal metatarsal joint can be accomplished in many ways. The compressive force attained between various constructs remains unclear. This study compares compression achieved through a locking/compression Lapidus plate both with and without the addition of a lag screw. Methods: A dorsal medial Lapidus/locking compression plate (Total Compression Plate System, OrthoPro, Salt Lake City, UT, now Wright Medical) was applied to one cadaveric limb, while the same plate with the addition of a 4.0-mm cannulated lag screw was applied to the contralateral limb for a total of 5 matched pairs of cadaveric specimens. Compressive force was recorded over time and compared between the constructs using a compression sensor (8" FlexiForce Resistive Force Sensor, Phidgets Inc, Calgary, Alberta, Canada). Results: Compression was maintained for 45.4 minutes in the plate only construct, and 317 minutes with the addition of the lag screw (P = .010). The mean time to 50% peak compression for the plate only construct was 4.90 minutes compared with 15.11 minutes for plate with lag screw construct (P = .012). Conclusion: The addition of a lag screw is recommended for extending the length of compression and possibly reducing nonweightbearing time and the risk of nonunion. Levels of Evidence: Level V.
Related Concept Videos
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Lagging Strand Synthesis
There are several major differences between synthesis of the leading strand and synthesis of the lagging strand. 1) Leading strand synthesis happens in the direction of replication fork opening, whereas lagging strand synthesis happens in the...
Lagging Strand Synthesis
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Fluid Pressure over Curved Plate of Constant Width
Steady, Laminar Flow Between Parallel Plates