Development of an ultrasound-guided technique for retrobulbar nerve block in dromedary camels: a cadaveric study
1Department of Veterinary Surgery, Anesthesiology and Radiology, Faculty of Veterinary Medicine, Benha University, Toukh, Egypt.
Objective:
Description of an ultrasound (US)-guided technique for retrobulbar nerve blockade in dromedary (Camelus dromedarius) cadavers.
Study Design:
Prospective experimental cadaveric study that was carried out in three phases: phase I: anatomical dissection and development of US-guided technique; phase II: methylene blue (MB) injection; phase III: contrast medium (CM), US-guided injections with computed tomography (CT) control.
Animals:
A total of 36 orbits from 18 heads were obtained from 18 dromedary cadavers.
Methods:
Phase I: anatomical dissections were carried out bilaterally, using two heads to determine needle site placement. Phase II: a US-guided, lateral, in-plane approach using one of three volumes of MB (3, 6, or 9 mL) was evaluated in six heads (four orbits per volume tested) to establish the ideal injection volume. Injections of MB that strongly stained all retrobulbar nerves were considered successful, whereas insufficient MB volumes resulted in weak or no nerve staining. Phase III: US-guided retrobulbar injection with CM was carried out using 20 orbits. Computed tomography was performed after each injection trial to determine the accuracy of needle placement and CM dispersal. An injection was judged to be successful when the CT images revealed that the needle was located within the retractor bulbi muscle cone and the CM reached the target nerves at the orbitorotundum and the optic foramina.
Results:
Only injection of 9 mL of MB stained the target nerves sufficiently, whereas there was no or only weak staining with 3 and 6 mL, respectively. Therefore, 9 mL of CM was used for the US-guided injections in phase III. Subsequent CT scans revealed satisfying CM distribution within the ocular muscle cone in 18 of 20 cases (90% success rate).
Conclusions And Clinical Relevance:
US-guided retrobulbar injection in dromedary cadavers is feasible. Further research is required to assess its practicality and usefulness in vivo.
More Related Videos
05:18Author Spotlight: Ultrasound-Guided Needle Release Combined with Corticosteroid Injection for the Treatment of Supinator Syndrome
Published on: May 26, 2023
07:44Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Block Diagram Reduction
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Elements of Block Diagrams
A block diagram typically includes essential elements such as comparators, blocks, and feedback loops. Each of these elements...
Sustainable Development
Relation between Mathematical Equations and Block Diagrams