Impact of Insulin Delivery Method on Hypoglycemia Incidence in Pediatric Type 1 Diabetes Mellitus Patients

Snijezana Hasanbegovic1, Emina Obarcanin2, Edo Hasanbegovic1

  • 1Pediatric Clinic, UCC Sarajevo, Sarajevo, Bosnia and Herzegovina.

Insights

Insulin pumps and pens show similar hypoglycemia rates in type 1 diabetes pediatric patients. Continuous glucose monitoring is more valuable than patient history for identifying hypoglycemia. Regular CGM is recommended for all T1DM patients annually.

Area of Science:

  • Pediatric Endocrinology
  • Metabolic Disorders
  • Diabetes Management

Background:

  • Managing type 1 diabetes mellitus (T1DM) in children presents unique challenges due to growth, development, and varied daily activities.
  • Optimizing insulin delivery is crucial for preventing hypoglycemia in pediatric T1DM patients.

Purpose of the Study:

  • To compare the effectiveness of insulin pump therapy versus insulin pen therapy in preventing hypoglycemia.
  • To evaluate the role of continuous glucose monitoring (CGM) versus patient history in identifying hypoglycemia in pediatric T1DM.

Main Methods:

  • A 3-year study involving 149 pediatric patients (up to 18 years) with T1DM.
  • Patients were divided into two groups: insulin pump therapy and insulin pen therapy.
  • Hypoglycemia was assessed using patient history and continuous glucose monitoring (CGM) data.

Main Results:

  • No significant difference in hypoglycemia incidence was found between insulin pump and insulin pen users based on anamnesis (83.56% vs. 81.58%).
  • CGM records revealed a higher number of hypoglycemia episodes compared to historical data across both treatment groups.
  • The number of historical hypoglycemia episodes was slightly higher in the insulin pen group.

Conclusions:

  • Both insulin pump and pen therapies demonstrated comparable outcomes regarding hypoglycemia in pediatric T1DM patients.
  • Continuous glucose monitoring (CGM) is a more sensitive tool for detecting hypoglycemia and glycemia variability than patient history.
  • Annual CGM is recommended for all T1DM patients to monitor glycemia, identify unrecognized hypoglycemia, and predict long-term metabolic control.
Abstract

Related Concept Videos

Diabetes Mellitus: Type 2 and Gestational01:22

Diabetes Mellitus: Type 2 and Gestational

Type 2 diabetes, characterized by insulin resistance, arises when the insulin receptors on cells lose responsiveness to insulin, diminishing the cell's capacity to take up glucose, resulting in elevated blood glucose levels. To receive a diagnosis of Type 2 diabetes, a series of blood glucose tests are necessary to assess whether the blood glucose falls within normal parameters. If the result is out of the normal range, a patient may be diagnosed as prediabetic or diabetic, depending on the...
5.1K
Diabetes Mellitus: Overview and Type I Subtype01:22

Diabetes Mellitus: Overview and Type I Subtype

Diabetes mellitus is a chronic metabolic disorder characterized by high blood glucose levels due to inadequate insulin production, insulin resistance, or both. The condition affects millions worldwide and can significantly impact their health and quality of life.
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
5.5K
Insulin Formulations: Types and Delivery01:27

Insulin Formulations: Types and Delivery

Insulin preparations are categorized by their duration of action into short-acting and long-acting types. Two strategies are used to modify insulin's absorption and pharmacokinetic profile: slowing the absorption post-subcutaneous injection, or altering human insulin's amino acid sequence or protein structure. These changes retain the insulin's ability to bind to the insulin receptor, but alter its behavior in solution or after injection.
Short-acting insulins are divided into...
800
Types of Reports II: Incident or Occurrence Report01:21

Types of Reports II: Incident or Occurrence Report

An Incident or Occurrence Report in a healthcare setting is a crucial document used to record any unexpected occurrence that may or may not have affected a patient, employee, or visitor. Such reports are critical to improving patient safety and include all details leading up to and including the event.
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
1.3K
Types of Impact01:30

Types of Impact

Impacts can be classified in various forms, primarily under two subgroups: central impact and oblique impact. A central impact occurs when two objects collide head-on, possessing opposite velocities aligned along the line of impact. Conversely, an oblique impact occurs when two objects collide at an angle, resulting in a modification of both direction and velocity.
The coefficient of restitution is a metric for understanding the dynamics of impacts. It quantifies the ratio of relative velocity...
1.1K
Pharmacokinetics in Pediatric Patients: Drug Excretion01:26

Pharmacokinetics in Pediatric Patients: Drug Excretion

In pediatric medicine, understanding the renal function and drug elimination nuances is crucial for administering safe and effective treatments. Newborns, in particular, display markedly slower renal functions than adults, profoundly affecting how drugs are cleared from their bodies. This slower drug clearance requires clinicians to extend the dosing intervals for many medications to prevent drug accumulation and toxicity while ensuring therapeutic efficacy.One key area where these adjustments...
279