Variation of Coma Aberration With Prismatic Soft Contact Lenses
Carlos Carpena-Torres1, José Manuel López-Alonso, Mercedes Burgos-Martínez
1Departments of Optics II (Optometry and Vision) (C.C.-T., G.C., J.C.-A.), and Optics I (J.M.L.-A.), Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain; and mark'ennovy Personalized Care (M.B.-M.), Madrid, Spain.
Purpose:
To analyze the variation in vertical coma and the rest of ocular aberrations before and after fitting prismatic soft contact lenses (PSCL).
Methods:
Thirty-seven eyes of 20 healthy subjects (24.30±2.03 years) were evaluated to analyze the variation in ocular wavefront aberrations before and after fitting PSCL of different base-down prism values (1.0, 1.5, and 2.0 prism diopters [PD]), designed to study its influence in the compensation of vertical coma aberration. A Hartmann-Shack sensor with a wavelength of 780 nm was used, considering a pupil size of 3 mm. In addition, the influence of PSCL in visual function under photopic conditions in terms of high-contrast visual acuity and contrast sensitivity was evaluated.
Results:
There was statistically significant differences (P<0.05) in ocular aberrations from first to seventh order after fitting PSCL, but only the differences in vertical tilt, horizontal tilt, defocus, vertical astigmatism, and vertical coma were clinically relevant (Strehl ratio <0.8). The mean of vertical coma (μm) was 0.022±0.030 for control, 0.045±0.064 for 1.0 PD (P=0.645), 0.048±0.053 for 1.5 PD (P=0.037), and 0.074±0.047 for 2.0 PD (P<0.001). The changes in visual function under photopic conditions were not clinically relevant.
Conclusions:
PSCL induce a magnitude of vertical coma aberration directly proportional to prism value without affecting the rest of ocular high-order aberrations.
Related Concept Videos
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Design of Prismatic Beams for Bending
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...