Determinants of radiation dose during right transradial access: Insights from the RAD-MATRIX study
Alessandro Sciahbasi1, Enrico Frigoli2, Alessandro Sarandrea3
1Interventional Cardiology, Sandro Pertini Hospital, ASL RM2, Rome, Italy.
Background:
The RAD-MATRIX trial reported a large operator radiation exposure variability in right radial percutaneous coronary procedures. The reasons of these differences are not well understood. Our aim was to appraise the determinants of operator radiation exposure during coronary right transradial procedures.
Methods:
Patient arrangement during transradial intervention was investigated across operators involved in the RAD-MATRIX trial. Operator radiation exposure was analyzed according to the position of the patient right arm (close or far from the body) and in relation to the size of the upper leaded glass.
Results:
Among the 14 operators who agreed to participate, there was a greater than 10-fold difference in radiation dose at thorax level (from 21.5 to 267 μSv) that persisted after normalization by dose-area product (from 0.35 to 3.5 μSv/Gy*cm2). Among the operators who positioned the instrumented right arm far from the body (110.4 μSv, interquartile range 71.5-146.5 μSv), thorax dose was greater than that in those who placed the instrumented arm close to the right leg (46.1 μSv, 31.3-56.8 μSv, P = .02). This difference persisted after normalization by dose-area product (P = .028). The use of a smaller full glass shield was also associated with a higher radiation exposure compared with a larger composite shield (147.5 and 60 μSv, respectively, P = .016).
Conclusions:
In the context of the biggest radiation study conducted in patients undergoing transradial catheterization, the instrumented right arm arrangement close to the leg and greater upper leaded shield dimensions were associated with a lower operator radiation exposure. Our findings emphasize the importance of implementing simple preventive measures to mitigate the extra risks of radiation exposure with right radial as compared with femoral access.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Bioavailability Study Design: Single Versus Multiple Dose Studies
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Radiation: Applications
The average...