Related Experiment Video
Updated: Feb 14, 2026

Negative Additive Manufacturing of Complex Shaped Boron Carbides
Published on: September 18, 2018
Quantitative analysis of prompt gamma ray imaging during proton boron fusion therapy according to boron concentration
Han-Back Shin1, Moo-Sub Kim1, Sunmi Kim1
1Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Abstract:
The purpose of this study is to evaluate the prompt gamma ray imaging technique according to the clinical boron concentration range during proton boron fusion therapy (PBFT). To acquire a prompt gamma ray image from 32 projections, we simulated four head single photon emission computed tomography and a proton beam nozzle using a Monte Carlo simulation. We used modified ordered subset expectation maximization reconstruction algorithm with a graphic processing unit for fast image acquisition. Boron concentration was set as 20 to 100 μg at intervals of 20 μg. For quantitative analysis of the prompt gamma ray image, we acquired an image profile drawn through two boron uptake regions (BURs) and calculated the contrast value, signal-to-noise ratio (SNR), and difference between the physical target volume and volume of the prompt gamma ray image. The relative counts of prompt gamma rays were noticeably increased with increasing boron concentration. Although the intensities on the image profiles showed a similar tendency according to the boron concentration, the SNR and contrast value were improved with increasing boron concentration. This study suggests that a tumor monitoring technique using prompt gamma ray detection can be clinically applicable even if the boron concentration is relatively low.
More Related Videos
13:09Assessment of Boron Doped Diamond Electrode Quality and Application to In Situ Modification of Local pH by Water Electrolysis
Published on: January 6, 2016
08:46Regioselective O-Glycosylation of Nucleosides via the Temporary 2',3'-Diol Protection by a Boronic Ester for the Synthesis of Disaccharide Nucleosides
Published on: July 26, 2018
Related Concept Videos
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
X-ray Imaging
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Atomic Mass