Performance of a second generation pulmonary capnotracking system for continuous monitoring of cardiac output
Philip J Peyton1,2, Monique Kozub3,4
1Department of Anaesthesia, Austin Health, Heidelberg, Melbourne, VIC, 3084, Australia. phil.peyton@austin.org.au.
Abstract:
Technologies for minimally-invasive cardiac output measurement in patients during surgery remain little used in routine practice. We tested a redeveloped system based on CO2 elimination (VCO2) by the lungs for use in ventilated patients, which can be seamlessly integrated into a modern anesthesia/monitoring platform, and provides automated, continuous breath-by-breath cardiac output monitoring. A prototype measurement system was constructed to measure VCO2 and end-tidal CO2 concentration with each breath. A baseline measurement of non-shunt cardiac output was made during a brief oscillating change in ventilator rate, according to the differential CO2 Fick approach and repeated at 5-10 min intervals. Continuous breath-by-breath monitoring of cardiac output was performed between these intervals from measurement of VCO2, using a derivation of the Fick equation applied to pulmonary CO2 elimination and cardiac output displayed in real time. Measurements were compared with simultaneous measurements by thermodilution in 50 patients undergoing cardiac surgery or liver transplantation. Overall mean bias [sd] for agreement in cardiac output measurement was - 0.3 [1.1] L/min, percentage error ± 38.7%, intraclass correlation coefficient = 0.91. Concordance in measurement of changes of at least 15% in cardiac output was 81.4%, with a mean angular bias of - 1.7°, and radial limits of agreement of ± 76.2° on polar plot analysis. The accuracy and precision compared favourably to other clinical techniques. The method is relatively seamless and automated and has potential for continuous, cardiac output monitoring in ventilated patients during anesthesia and critical care.
More Related Videos
11:03Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
09:56Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example
Published on: November 18, 2015
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Pathophysiology of Cardiac Performance