Related Experiment Video
Updated: Feb 14, 2026

Bacterial Detection & Identification Using Electrochemical Sensors
Published on: April 23, 2013
An electrochemical immunosensor based on a 3D carbon system consisting of a suspended mesh and substrate-bound
Deepti Sharma1, Jongmin Lee1, Heungjoo Shin1
1Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea.
Abstract:
We developed an electrochemical redox cycling-based immunosensor using a 3D carbon system consisting of a suspended mesh and substrate-bound interdigitated array (IDA) nanoelectrodes. The carbon structures were fabricated using a simple, cost-effective, and reproducible microfabrication technology known as carbon microelectromechanical systems (C-MEMS). We demonstrated that the 3D sub-micrometer-sized mesh architecture and selective modification of the suspended mesh facilitated the efficient production of large quantities of electrochemical redox species. The electrochemically active surfaces and small size of IDA nanoelectrodes with a 1:1 aspect ratio exhibited high signal amplification resulting from efficient redox cycling of electrochemical species (PAP/PQI) by a factor of ~25. The proposed selective surface modification scheme facilitated efficient redox cycling and exhibited a linear detection range of 0.001-100 ng/mL for cardiac myoglobin (cMyo). The specific detection of cMyo was also achieved in the presence of other interfering species. Moreover, the proposed 3D carbon system-based immunosensor successfully detected as low as ~0.4 pg/mL cMyo in phosphate-buffered saline and human serum.
More Related Videos
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
The Carbon Cycle
Carbon Skeletons
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...

