Reinforcing the Importance and Feasibility of Implementing a Low-dose Protocol for CT-guided Biopsies
Eric J Keller1, Robert J Lewandowski2, Lee Goodwin3
1Department of Radiology, Division of Cardiovascular Imaging, Northwestern University, 737 N. Michigan Ave. Suite 1600, Chicago, IL 60611.
Rationale And Objectives:
This study sought to more definitely illustrate the impact and feasibility of implementing a low-dose protocol for computed tomography (CT)-guided biopsies using size-specific dose estimates and multivariate analyses.
Materials And Methods:
Fifty consecutive CT-guided lung and extrapulmonary biopsies were reviewed before and after implementation of a low-dose protocol (200 patients total, mean age 61 ± 15 years, 128 women). Analyses of variance with Bonferroni correction were used to compare standard and low-dose protocols in terms of patient demographics, physician experience, target lesion size, total dose-length product, total acquisitions, size-specific dose estimate, signal-to-noise ratio, contrast-to-noise ratio, and lesion conspicuity ratings. All procedures were performed on the same 16-slice CT scanner.
Results:
Voluntary protocol adherence was 100% (lung) and 89% (extrapulmonary). The low-dose protocol achieved significantly lower total average dose-length product [(lung) 735.6 ± 599.4 mGy × cm to 252.1 ± 101.9 mGy × cm, P < .001; (extrapulmonary) 724.7 ± 545.0 mGy × cm to 392.9 ± 239.5 mGy × cm, P < .001] and size-specific dose estimate [(lung) 5.2 ± 0.8 mGy × cm to 4.3 ± 1.5 mGy, P < .001; (extrapulmonary) 10.1 ± 6.7 mGy to 6.5 ± 2.7 mGy, P < .001]. Only the change in protocol was independently associated with lower size-specific dose estimates when controlling for the other variables (P < .0001). This was achieved with no significant differences in signal-to-noise ratio, contrast-to-noise ratio, or lesion conspicuity.
Conclusions:
Implementation of a low-dose protocol for CT-guided biopsies resulted in 21% and 36% of size-specific dose estimate reduction for lung and extrapulmonary biopsies, respectively, with excellent adherence. Interventional and body radiologists should implement low dose CT-guidance protocols aiming to improve patient safety.
Related Concept Videos
Reinforcement
Positive reinforcement occurs when a behavior is followed by the presentation of a rewarding stimulus, increasing the frequency of that behavior. For example:
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Reinforcement Schedules
Once a behavior is learned,...
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.
Reinforcements in Concrete
Fiber Reinforced Concrete