Background:
Intertrochanteric fractures are of great interest worldwide and are the most frequently operated fractures. Intramedullary nailing is commonly used in the treatment of intertrochanteric fractures. The purpose of this study is to assess the necessity of using the distal blocking screw in 31-A1 and 31-A2 fractures, classified according to the Orthopaedic Trauma Association classification system (AO/OTA).
Methods:
This is a prospective study of 143 consecutive patients (mean age 85.01 years, mean final follow-up 14.1 months) surgically treated with the same intramedullary nail. In 75 cases, the distal locking screw was not used. Parameters evaluated during follow-up were: blood loss, transfusion requirements, surgery duration, and fluoroscopy time. Harris Hip Score and Barthel Activity Daily Living were used for the clinical evaluation. Radiographic Union Score For Hip (RUSH score) and Tip apex distance (TAD) were measured for radiologic evaluation.
Results:
The group treated without locking screw showed significantly shorter surgical duration time (31.9 vs. 47.2 min), a decrease in blood loss (variation Hb - 1.06 vs. - 1.97), and reduced X-rays exposure time (25.4 vs. 31.6 s). No significant differences were observed in the postoperative period and in the radiographic and clinical scores.
Conclusion:
This study demonstrates that in intertrochanteric 31-A1 and 31-A2 stable fractures, the absence of distal locking screw does not compromise bone healing and prevents several clinical complications.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Accessory Structures of the Skin: Nails
The main components of a nail include the following.
Nail Plate: The nail plate is the visible portion of the nail that extends beyond the fingertips or toes. It is a hard, translucent...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons