Related Experiment Video
Updated: Feb 14, 2026

Monitoring Blood-Brain Barrier Opening in Rats with a Preclinical Focused Ultrasound System
Published on: September 13, 2024
Velocimetric ultrasound thermometry applied to myocardium protection monitoring
Céline Engrand1, Didier Laux1, Jean-Yves Ferrandis2
1University of Montpellier, IES UMR 5214, 860 Rue Saint Priest, CC 05 003, F-34000 Montpellier, France; CNRS, IES UMR 5214, 860 Rue Saint Priest, CC 05 003, F-34000 Montpellier, France.
Abstract:
Tissue temperature control during cardiac surgery is crucial for myocardial protection. To preserve the tissue, a hypothermic cardioplegia is applied in order to decrease the heart temperature down to around 10°C. The monitoring of the thermal evolution of the myocardium is then of importance to minimize deleterious effects on the heart. The present work aims at evaluating the potential of an ultrasonic velocimetric thermometry on the monitoring of in vitro tissues heating. An indentation process is first proposed to identify the experimental linear relationship linking, in myocardia, the speed of the ultrasonic longitudinal wave to the tissue temperature. An extension of this method based on the echo-tracking principle is then proposed to approach surgical conditions. Temperature changes are measured by monitoring the induced time delays of backscattered ultrasonic echoes. These results are compared to T-type thermocouple reference measurements. They are then discussed in terms of measurement precision and in situ applications.
Related Concept Videos
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protecting Self-Esteem
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...

