Contrast Enhanced Vessel Imaging using MicroCT
Published on: January 27, 2011
Phantom-based study exploring the effects of different scatter correction approaches on the reconstructed images
Connor Puett1, Christina Inscoe2, Yueh Z Lee1,2,3
1University of North Carolina at Chapel Hill, UNC/NCSU Joint Department of Biomedical Engineering, Chapel Hill, North Carolina, United States.
Abstract:
Stationary digital breast tomosynthesis (sDBT) is an emerging technology in which the single rotating x-ray tube is replaced by a fixed array of multiple carbon nanotube-enabled sources, providing a higher spatial and temporal resolution. As such, sDBT offers a promising platform for contrast-enhanced (CE) imaging. However, given the minimal enhancement above background with standard operational tube settings and iodine dosing, CE breast imaging requires additional acquisition steps to isolate the iodine signal, using either temporal or dual energy subtraction (TS or DES) protocols. Also, correcting for factors that limit contrast is critical, and scatter and noise pose unique challenges during tomosynthesis. This phantom-based study of CE sDBT compared different postacquisition scatter correction approaches on the quality of the reconstructed image slices. Beam-pass collimation was used to sample scatter indirectly, from which an interpolated scatter map was obtained for each projection image. Scatter-corrected projections provided the information for reconstruction. Comparison between the application of different scatter maps demonstrated the significant effect that processing has on the contrast-to-noise ratio and feature detectability ([Formula: see text]) in the final displayed images and emphasized the critical importance of scatter correction during DES.
More Related Videos
Related Concept Videos
Distance Corrections
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Power Factor Correction
Bioavailability Enhancement: Determination and Conceptual Approaches in Overcoming Bioavailability Problems
Self-Evaluation: Self-Enhancement and Self-Verification
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...