Robotic Ablation of Atrial Fibrillation
Published on: May 29, 2015
Randomized controlled trial of Amigo® robotically controlled versus manually controlled ablation of the
Kurt S Hoffmayer1, Felix Krainski2, Sanjay Shah2
1Division of Cardiology, Cardiac Electrophysiology Program, UCSD Health System, University of California, San Diego, 9452 Medical Center Dr., MC7411, 3rd Floor, Room 3E-313, La Jolla, CA, 92037, USA. khoffmayer@ucsd.edu.
Background:
Radiofrequency catheter ablation (RFCA) of the cavo-tricuspid isthmus (CTI) is a common treatment for atrial flutter (AFL). However, achieving bi-directional CTI conduction block may be difficult, partly due to catheter instability.
Objective:
To evaluate the safety and efficacy of the Amigo® Remote Catheter System (RCS) compared to manual catheter manipulation, during CTI ablation for AFL.
Methods:
Fifty patients (pts) were prospectively randomized to robotically (25 pts) versus manually (25 pts) controlled catheter manipulation during CTI ablation, using a force-contact sensing, irrigated ablation catheter. The primary outcome was recurrence of CTI conduction after a 30-min waiting period. Secondary outcomes included total ablation, procedure, and fluoroscopy times, contact force measurement, and catheter stability.
Results:
Recurrence of CTI conduction 30 min after ablation was less with robotically (0/25) versus manually (6/25) controlled ablation (p = 0.023). Total ablation and procedure times to achieve persistent CTI block (6.7 ± 3 vs. 7.4 ± 2.5 min and 14.9 ± 7.5 vs. 15.2 ± 7 min, respectively) were not significantly different (p = 0.35 and p = 0.91, respectively). There was a non-significant trend toward a greater force time integral (FTI in gm/s) with robotically versus manually controlled CTI ablation (571 ± 278 vs. 471 ± 179, p = 0.13). Fluoroscopy time was longer with robotically versus manually controlled CTI ablation (6.8 ± 4.4 min vs. 3.8 ± 2.3 min, p = 0.0027). There were no complications in either group.
Conclusion:
Robotically controlled CTI ablation resulted in fewer acute recurrences of CTI conduction compared to manually controlled CTI ablation, and a trend toward higher FTI. The longer fluoroscopy time during robotically controlled ablation was likely due to a steep learning curve.
Trial Registration:
Clinicaltrials.gov Identifier: NCT02467179.
More Related Videos
Related Concept Videos
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Combinatorial Gene Control
The expression of more than 30,000 genes is controlled by approximately 2000-3000 transcription factors. This is possible because a single transcription factor can recognize more than one regulatory sequence. The specificity in gene...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Control Systems
At the heart...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
PID Controller