Prevalence of Infection-Competent Serogroup 6 Legionella pneumophila within Premise Plumbing in Southeast Michigan
Related Experiment Video
Updated: Feb 14, 2026

Use of Galleria mellonella as a Model Organism to Study Legionella pneumophila Infection
Published on: November 22, 2013
Brenda G Byrne1, Sarah McColm1, Shawn P McElmurry2
1Department of Microbiology and Immunology, University of Michigan, Ann Arbor, Michigan, USA.
Abstract:
Coinciding with major changes to its municipal water system, Flint, MI, endured Legionnaires' disease outbreaks in 2014 and 2015. By sampling premise plumbing in Flint in the fall of 2016, we found that 12% of homes harbored legionellae, a frequency similar to that in residences in neighboring areas. To evaluate the genetic diversity of Legionella pneumophila in Southeast Michigan, we determined the sequence type (ST) and serogroup (SG) of the 18 residential isolates from Flint and Detroit, MI, and the 33 clinical isolates submitted by hospitals in three area counties in 2013 to 2016. Common to one environmental and four clinical samples were strains of L. pneumophila SG1 and ST1, the most prevalent ST worldwide. Among the Flint premise plumbing isolates, 14 of 16 strains were of ST367 and ST461, two closely related SG6 strain types isolated previously from patients and corresponding environmental samples. Each of the representative SG1 clinical strains and SG6 environmental isolates from Southeast Michigan infected and survived within macrophage cultures at least as well as a virulent laboratory strain, as judged by microscopy and by enumerating CFU. Likewise, 72 h after infection, the yield of viable-cell counts increased >100-fold for each of the representative SG1 clinical isolates, Flint premise plumbing SG6 ST367 and -461 isolates, and two Detroit residential isolates. We verified by immunostaining that SG1-specific antibody does not cross-react with the SG6 L. pneumophila environmental strains. Because the widely used urinary antigen diagnostic test does not readily detect non-SG1 L. pneumophila, Legionnaires' disease caused by SG6 L. pneumophila is likely underreported worldwide.IMPORTANCEL. pneumophila is the leading cause of disease outbreaks associated with drinking water in the United States. Compared to what is known of the established risks of colonization within hospitals and hotels, relatively little is known about residential exposure to L. pneumophila One year after two outbreaks of Legionnaires' disease in Genesee County, MI, that coincided with damage to the Flint municipal water system, our multidisciplinary team launched an environmental surveillance and laboratory research campaign aimed at informing risk management strategies to provide safe public water supplies. The most prevalent L. pneumophila strains isolated from residential plumbing were closely related strains of SG6. In laboratory tests of virulence, the SG6 environmental isolates resembled SG1 clinical strains, yet they are not readily detected by the common diagnostic urinary antigen test, which is specific for SG1. Therefore, our study complements the existing epidemiological literature indicating that Legionnaires' disease due to non-SG1 strains is underreported around the globe.
Insights
Legionella pneumophila (L. pneumophila) strains, particularly SG6, were found in Flint homes after water system changes. These strains are virulent and may be underreported due to diagnostic test limitations.
Area of Science:
- Environmental microbiology
- Public health
- Infectious diseases
Background:
- Legionnaires' disease outbreaks occurred in Flint, MI, coinciding with municipal water system changes.
- Residential exposure to Legionella pneumophila (L. pneumophila) is less understood than hospital or hotel settings.
- L. pneumophila is a leading cause of drinking water-associated disease outbreaks in the U.S.
Purpose of the Study:
- To investigate the genetic diversity of L. pneumophila in Southeast Michigan residential and clinical isolates.
- To assess the virulence of environmental L. pneumophila strains compared to clinical strains.
- To highlight potential underreporting of Legionnaires' disease caused by non-serogroup 1 strains.
Main Methods:
- Collected and analyzed residential plumbing samples from Flint and Detroit, MI.
- Determined sequence types (ST) and serogroups (SG) of L. pneumophila isolates.
- Evaluated isolate virulence through macrophage infection and cell culture assays.
- Used immunostaining to differentiate L. pneumophila serogroups.
Main Results:
- L. pneumophila was found in 12% of Flint homes sampled.
- Closely related SG6 strains (ST367 and ST461) were prevalent in Flint residential plumbing.
- Both SG1 clinical and SG6 environmental isolates demonstrated virulence in laboratory tests.
- The common urinary antigen test does not readily detect non-SG1 L. pneumophila.
Conclusions:
- SG6 L. pneumophila strains are present in residential plumbing and possess virulence similar to SG1 strains.
- Legionnaires' disease caused by non-SG1 L. pneumophila may be underreported globally due to diagnostic limitations.
- Findings inform risk management strategies for safe public water supplies.
Related Concept Videos
Prevalence and Incidence
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...
Design Example: Designing a Residential Plumbing System
Infection
The chain begins with pathogens: bacteria, viruses, fungi, prions, or parasites such as protozoa helminths. These can be present on the skin as transient or resident flora, or they can be acquired from the environment. Identifying and treating the type of infection and...
Stages of Infection
Defense Mechanism Against Infection
In addition, many body organ systems have unique defenses against infection. The skin is an intact, multilayered surface preventing invasion by microorganisms unless impaired. Mucous membranes lining the mouth, nose, and eyelids are barriers...
Sexually Transmitted Infections