Evaluation of Postoperative Stability After Open Reduction and Internal Fixation of Zygomaticomaxillary Complex
Hyo-Jung Kim1, Kyung-Hwan Bang1, Eun-Ji Park2
1Department of Oral and Maxillofacial Surgery, Ulsan University Hospital, University of Ulsan College of Medicine.
Abstract:
The aim of this study was to evaluate whether the amount of fracture displacement affects postoperative stability of isolated zygomaticomaxillary complex fractures and to determine whether the 1-point fixation method is as stable as 2- or 3-point fixation methods. The authors investigated 14 patients with 1-point fixation in the zygomaticomaxillary area (group A), 14 patients with 2-point fixation in the zygomaticomaxillary and frontozygomatic area (group B), and 13 patients with 3-point fixation in the zygomaticomaxillary, frontozygomatic, and infraorbital rim area (group C). Stability of the reduced zygomaticomaxillary complex was assessed by comparing immediate postoperative cone beam computed tomography images with those obtained at least 3 months later. Preoperatively, the total mean displacement was 3.79 ± 1.36 mm in group A, 3.43 ± 0.89 mm in group B, and 3.86 ± 1.57 mm in group C. The total postoperative orbital and screw changes were 0.91 ± 0.18 and 0.72 ± 0.08 mm, respectively, in group A; 0.92 ± 0.19 and 0.68 ± 0.09 mm, respectively, in group B; and 0.91 ± 0.11 and 0.66 ± 0.10 mm, respectively, in group C. There were no significant relationships between postoperative stability and amount of fracture displacement in any of the 3 groups, or between the 3 groups (P > 0.05). There was little difference in postoperative stability between the 3 groups. Hence, the amount of displacement is not a very important consideration when deciding the fixation method, including the number and location of miniplates applied for fixation.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Complexation Equilibria: Factors Influencing Stability of Complexes
Imaging Studies III: Computed Tomography
Internal Receptors
mRNA Stability and Gene Expression
Cis-acting Elements involved in mRNA stability
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...


