Related Experiment Video
Updated: Feb 14, 2026

Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Temperature controlled ionic liquid aqueous two phase system combined with affinity capillary electrophoresis for
Deia Abd El-Hady1, Hassan M Albishri2
1Chemistry Department, Faculty of Science, University of Jeddah, P.O. 80327, 21589 Jeddah, Saudi Arabia.
Abstract:
Temperature controlled ionic liquid aqueous two phase system (ILATPS) was used to improve the precision of pharmaceutical-AGP (human alpha (α1)-acid glycoprotein) binding measurements by affinity capillary electrophoresis (ACE). The effect of different types of short-chain alkyl imidazolium ILs within the concentration range of 10.0-1000.0 μmol L-1 on a propranolol (PRO)-AGP model was firstly investigated by ILATPS/ACE system. Use of 100.0 μmol L-1 1-butyl-3-methylimidazolium chloride (BMImCl) in 67.0 mmol L-1 potassium phosphate buffer (pH 7.4) containing low concentrations of AGP (5.0-100.0 µmol L-1) gave the highest precision value (2.98 ± 0.14 × 105 L/mol) which is in concord with the reported one (3.00 × 105) under similar experimental conditions. The proposed BMImCl/phosphate solution was a unique temperature controlled system to preserve AGP activity during the pre-analysis and within ACE measurements under lab conditions for about 30 days. This period could be prolonged by converting the one-phase solution into biphasic solution at 4 °C storage temperature and again it could get rapidly back into one-phase by raising the temperature with gentle shaking. This behavior could be attributed to the electrostatic interaction and π-π interaction between BMIm cations and negatively charged AGP ions (pI = 2.7). Moreover, the compatibility of ILATPS with ACE has been the critical factor to avoid precipitation of salts formed by anion exchange in the running buffer. The current ILATPS/ACE system was further used to rapidly and precisely estimate the binding constants of anticancer drugs methotrexate (MTX) and vinblastine (VBL) with human AGP. The obtained binding values have been in good agreements with their findings by high performance affinity chromatography (HPAC). This ILATP/ACE system could similarly be applied to improve the precision of other proteins binding measurements with consuming a small amount of protein and with shortening ACE analysis time.
More Related Videos
08:10A Liquid Phase Affinity Capture Assay Using Magnetic Beads to Study Protein-Protein Interaction: The Poliovirus-Nanobody Example
Published on: May 29, 2012
11:04Synthesis of Ionic Liquid Based Electrolytes, Assembly of Li-ion Batteries, and Measurements of Performance at High Temperature
Published on: December 20, 2016
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Chemical Reactions in Aqueous Solutions
Rise of Liquid in a Capillary Tube
Ionic Bonds
When atoms gain or lose electrons to achieve a more stable electron configuration they form ions. Ionic bonds are electrostatic attractions between ions with opposite charges. Ionic compounds are rigid and brittle when solid and may dissociate into their constituent ions in water. Covalent compounds, by contrast, remain intact unless a chemical reaction breaks them.
Opposing Charges Hold Ions Together in Ionic Compounds
Ionic bonds are reversible electrostatic interactions between ions...
Aqueous Solutions and Heats of Hydration
When ionic compounds dissolve in water, the ions in the solid separate and disperse uniformly throughout the solution because water molecules surround and solvate the ions, reducing the strong electrostatic forces between them. This process...