Characteristics of Single-Loop Macroreentrant Biatrial Tachycardia Diagnosed by Ultrahigh-Resolution Mapping System
Takeshi Kitamura1, Ruairidh Martin1, Arnaud Denis2
1From the Department of Cardiac Electrophysiology, Service de Rythmologie, Hôpital Cardiologique du Haut-Lévêque (Centre Hospitalier Universitaire de Bordeaux), Avenue de Magellan, 33604, Bordeaux-Pessac, France (T.K., R.M., A. Denis, M.T., A.F., N.T., G.M., G.C., M.W., K.V., C.A.M., N.A.J., J.D., N.K., T.P., F.S., H.C., M. Hocini, M. Haïssaguerre, P.J., N.D.); and Unité INSERM U1048, University Hospital Rangueil, Toulouse, France (A. Duparc, A.R., P.M.). take1124@hotmail.co.jp.
Background:
Biatrial tachycardia (BiAT) is a rare form of atrial macroreentrant tachycardia, in which both atria form a critical part of the circuit. We aimed to identify the characteristics and precise circuits of single-loop macroreentrant BiATs.
Methods And Results:
We identified 8 patients (median age, 59.5 years old) with 9 BiATs in a cohort of 336 consecutive patients from 2 institutions who had undergone AT catheter ablation using an automatic ultrahigh-resolution mapping system. Seven of the 8 patients had a history of persistent AF ablation, including septal or anterior left atrium ablation before developing BiAT. One of the 8 patients had a history of an atrial septal patch closure with a massively enlarged right atrium. Nine ATs (median cycle length, 334 ms; median 12 561 points in the left atrium; 8814 points in the right atrium) were diagnosed as single-loop macroreentrant BiATs. We observed 3 types of BiAT (1) BiAT with a perimitral and peritricuspid reentrant circuit (n=3), (2) BiAT using the right atrium septum and a perimitral circuit (n=3), and (3) BiAT using only the left atrium and right atrium septum (n=3). Catheter ablation successfully terminated 8 of the 9 BiATs.
Conclusions:
All patients who developed BiAT had an electric obstacle on the anteroseptal left atrium, primarily from prior ablation lesions. In this situation, mapping of both atria should be considered during AT. Because 3 types of single-loop BiAT were observed, ablation strategies should be adjusted to the type of BiAT circuit.
More Related Videos
09:36Dual-Dye Optical Mapping of Hearts from RyR2R2474S Knock-In Mice of Catecholaminergic Polymorphic Ventricular Tachycardia
Published on: December 22, 2023
10:10Ultrahigh Resolution Mouse Optical Coherence Tomography to Aid Intraocular Injection in Retinal Gene Therapy Research
Published on: November 2, 2018
Related Concept Videos
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Characteristics of Life
Feedback Loops
Characteristics of Fluids
Characteristics of Fluids
Fluids, which include both liquids and gases, are substances that deform continuously under shearing stress. For example, water and oil are liquids with molecules that can...
Characteristics of BJT
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...