Related Experiment Video
Updated: Feb 14, 2026

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Increased precision of coronal plane outcomes in robotic-assisted total knee arthroplasty: A systematic review and
Ashim Mannan1, James Vun1, Christopher Lodge1
1Mid Yorks NHS Trust, UK.
Background:
Inaccuracy of component alignment in total knee arthroplasty adversely impacts outcomes. Robotic systems improve translation of pre-operative planning to intra-operative steps, theoretically resulting in greater accuracy and precision. In this study we systematically review literature data of alignment outcomes and apply meta-analysis methods to assess whether robotic-assisted knee arthroplasty provides superior outcomes when compared to conventional knee prostheses.
Methods:
A PRISMA compliant search comparing alignment outcomes in robotic vs conventional knee arthroplasty was performed. Primary outcome measures were; number of three degree outliers and mean deviation from a neutral post-operative mechanical axis.
Results:
In total, from five studies reporting upon 402 knees, a post-operative mechanical axis malalignment of >3° occurred in 1/181 (0.006%) of robotic knees, and 42/159 (26.4%) of conventional knees with a meta-analysis odds ratio of 0.04 (95% CI 0.01-0.14), p < 0.00001 favouring robotic-assisted instrumentation. Meta-analysis also demonstrated weighted mean differences of post-operative mechanical axis alignment to be significantly more accurate in the robotic knee group: mean difference -0.63 (95% CI: -1.18,-0.08), z = 2.25, p = 0.02. Sensitivity analysis with inclusion of only Level 1 studies showed similar findings.
Conclusions:
This systematic review and meta-analysis demonstrates clear evidence of increased accuracy of alignment in robotic-assisted knee arthroplasty with specific regard to reconstituting a neutral mechanical axis and minimising number of outliers in the coronal plane. Further studies and long term data is required in order to conclude on survivorship and functional outcomes.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Work Done Over an Inclined Plane
The work done by gravity to move a rigid body, or the work done by an opposing force to move a rigid body against gravity, can be calculated using the center-of-mass framework. It is the line integral of the force of gravity over the path, considered positive if...