Related Experiment Video
Updated: Feb 14, 2026

06:14
Translational Rabbit Model of Chronic Cardiac Pacing
Published on: January 6, 2023
3.1K
Pacing in a 94-year-old runner during a 6-hour run
Beat Knechtle1,2, Pantelis T Nikolaidis3
1Medbase St. Gallen Am Vadianplatz, St. Gallen, Switzerland.
Open Access Journal of Sports Medicine
|February 15, 2018
Summary
This case report details the pacing strategy of a 94-year-old male runner in a 6-hour race, preparing for a marathon. His running speed decreased linearly, with physiological markers showing expected changes post-exertion.
Area of Science:
- Gerontology
- Sports Medicine
- Physiology
Background:
- Limited data exists on the pacing and physiological responses of ultra-endurance runners aged 90 and above.
- Understanding these aspects is crucial for supporting athletic longevity and performance in extreme age groups.
Observation:
- A 94-year-old male runner completed 24.304 km in a 6-hour race, demonstrating a nearly linear decrease in running speed over time.
- Physiological markers including body mass, body fat percentage, and fat-free mass showed slight decreases, while blood markers like hemoglobin and hematocrit increased post-race.
Findings:
- Running speed declined significantly, averaging 5.3±0.4 km/h in the first hour and 3.5±1.4 km/h in the last hour (p=0.015).
- Post-race, C-reactive protein peaked on day 1, creatine kinase remained elevated for 4 days, and creatinine/potassium normalized during recovery.
Implications:
- Extrapolation suggests a marathon finish time between 8.3 to over 11 hours for this M95 age group athlete.
- This case provides valuable insights into the physiological capabilities and endurance pacing of centenarian-aspiring marathoners.
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
2.9K
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
2.9K
Uncertainty in Measurement: Reading Instruments
54.2K
Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
54.2K
Hormonal Regulation
48.4K
Hormones regulate a significant portion of digestion through activation of the neuroendocrine system. The neuroendocrine system of digestion contains many different hormones all with multiple functions that are both, directly and indirectly, involved in digestion.
48.4K
Electron Configuration of Multielectron Atoms
65.4K
The alkali metal sodium (atomic number 11) has one more electron than the neon atom. This electron must go into the lowest-energy subshell available, the 3s orbital, giving a 1s22s22p63s1 configuration. The electrons occupying the outermost shell orbital(s) (highest value of n) are called valence electrons, and those occupying the inner shell orbitals are called core electrons. Since the core electron shells correspond to noble gas electron configurations, we can abbreviate electron...
65.4K
Energy-requiring Steps of Glycolysis
172.2K
Glucose is the source of nearly all energy used by organisms. The first step of converting glucose into usable energy is called glycolysis. Glycolysis occurs in the cytosol of the cell over two phases: an energy-requiring phase and an energy-releasing phase. Over the first three steps, glucose is converted into different forms and attached to two phosphate groups donated by two ATP molecules, resulting in an unstable sugar. In the next two stages, the unstable sugar splits into two sugar...
172.2K
Coordination Number and Geometry
19.1K
For transition metal complexes, the coordination number determines the geometry around the central metal ion. Table 1 compares coordination numbers to molecular geometry. The most common structures of the complexes in coordination compounds are octahedral, tetrahedral, and square planar.
19.1K

