Accuracy and feasibility of a dedicated image guidance solution for endoscopic lateral skull base surgery
Christoph Rathgeb1, Lukas Anschuetz2, Daniel Schneider1
1ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
Objective:
We aimed to design, build and validate a surgical navigation system which fulfills the accuracy requirements for surgical procedures on the ear and the lateral skull base, and which integrates with the endoscopic workflow and operating room setup.
Materials And Methods:
The navigation system consists of portable tablet computer (iPad Pro, Apple Computer, USA) and an optical tracking system (Cambar B1, Axios3D, Germany), both connected via a wireless Bluetooth link and attached directly to the OR table. Active optical tracking references are rigidly fixed to both the patient and surgical tools. Software to support image import, registration and 2D/3D visualization has been developed. Two models were used for targeting accuracy assessment: a technical phantom model and an ex vivo temporal bone model. Additionally, workflow integration and usability of the navigation system during endoscopic lateral skull base procedures was investigated in ex vivo experiments on 12 sides of cadaver head specimens.
Results:
The accuracy experiments revealed a target registration error in the technical phantom model of 0.20 ± 0.10 mm (n = 36) and during the ex vivo assessment of 0.28 ± 0.10 mm (n = 21). Navigation was successfully carried out in n = 36 procedures (infracochlear, suprageniculate and transpromontorial approach), with navigated instruments usable without interference with the endoscope. The system aided in the successful and accurate identification of vital anatomical structures.
Conclusions:
Useful surgical navigation is, to a large extent, a result of sufficiently accurate tracking technology. We have demonstrated sufficient accuracy and a potentially suitable integration for surgical application within endoscopic lateral skull base procedures.
Related Concept Videos
Weak Base Solutions
Strong Acid and Base Solutions
Improving Translational Accuracy
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Uncertainty in Measurement: Accuracy and Precision
Leveling Effect and Non-Aqueous Acid-Base Solutions
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):